1.4.4 Detent spring switch<br />

Using a suitable tool or by hand, set the<br />

detent disc to position N (Neutral).<br />

Mount position gauge 5p01 002 609 on<br />

the selector shaft and turn the gauge until<br />

the locating pin in the transmission housing<br />

engages in the gauge, then turn the<br />

knurled screw to eliminate play.<br />

Align the detent spring with centring<br />

device 5x46 001 250 and in this position<br />

screw the spring down.<br />

Tighten the screw at the output end first.<br />

(Tightening torques: see Chapter 1.5)<br />

With auxiliary tool 5w04 000 583 turn<br />

forward until distorsion angle is reached<br />

Unscrew the position gauge, move the<br />

selector shaft to all positions in turn and<br />

then move it back to position “N”.<br />

Note !<br />

If assembly was correct, it should be easy<br />

to push the position gauge on to the<br />

selector shaft until it makes contact with<br />

the transnission housing.<br />

1.4/26<br />

CD<br />

5 HP 19 FL © ZF Getriebe GmbH Saarbrücken<br />

00028<br />

00029<br />

00030<br />

00/08/01