described in Table III.E.1.b.i-1 below. Examples <strong>of</strong> batch splits using both types <strong>of</strong><br />

splitting protocols are given in Tables III.E.1.b.i-2 <strong>and</strong> III.E.1.b.i-3. We propose that the<br />

Proportional Protocol be required for cases in which the Equivalence Value <strong>of</strong> a<br />

renewable fuel is less than 1.0. For cases in which the Equivalence Value is equal to or<br />

greater than 1.0, we propose to allow parties the flexibility to follow a batch splitting<br />

protocol <strong>of</strong> their own choosing so long as there is at least one gallon-RIN for every<br />

physical gallon in each <strong>of</strong> the daughter batches. We request comment on these batch<br />

splitting protocols, any alternative protocols, <strong>and</strong> the need to codify a protocol in the<br />

regulations for specific situations.<br />

Table III.E.1.b.i-1<br />

Two batch splitting protocols<br />

Proportional One-to-one alignment<br />

Description The gallon-RINs assigned to a<br />

parent batch are split<br />

proportionally with the<br />

volumes in the daughter<br />

batches.<br />

Impacts for EV α < 1.0 Ratio <strong>of</strong> actual gallons to<br />

gallon-RINs in the parent<br />

batch is preserved in all<br />

daughter batches.<br />

Impacts for EV > 1.0 Ratio <strong>of</strong> actual gallons to<br />

gallon-RINs in the parent<br />

batch is preserved in all<br />

daughter batches.<br />

α<br />

Equivalence Value<br />

The gallon-RINs assigned to a<br />

parent batch are split to ensure<br />

that some daughter batches<br />

have a one-to-one<br />

correspondence between<br />

physical gallons <strong>and</strong> gallon-<br />

RINs. Remaining gallon-<br />

RINs are assigned to<br />

remaining gallons.<br />

Some daughter batches may<br />

have no assigned RIN.<br />

Ratio <strong>of</strong> actual gallons to<br />

gallon-RINs in some daughter<br />

batches will be different than<br />

the ratio for the parent batch.<br />

- 90 -