Tender Documents - Oil India Limited
Tender Documents - Oil India Limited
Tender Documents - Oil India Limited
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
(k)<br />
(l)<br />
(m)<br />
(n)<br />
ELEVATOR LINKS: Minimum 150 Ton (136 MT) capacity Welds less<br />
elevator links. The links should be compatible to Traveling block &<br />
Hook.<br />
ROTARY HOSE: Rotary hose of 2” / 3” ID, 3000 psi working<br />
pressure, 50 ft long, conforming to API Spec. 7K with safety clamps<br />
at both ends & necessary fittings for connection to stand pipe &<br />
swivel goose neck<br />
KELLY: Suitable Square / Hexagonal Kelly, 40 ft long to work inside<br />
5.1/2” OD (17-23 ppf) & 7” OD (23-29 ppf) Casings and compatible<br />
with rotary table. The Kelly should be complete with Kelly scabbard,<br />
matching Kelly bushing, upper & lower Kelly cock and Kelly saver<br />
sub.<br />
RIG ENGINE: Single or double, diesel engine capable of transmitting<br />
a minimum of 500 HP on intermittent duty in total to the draw<br />
Works. While calculating HP of the engine (s), the entire load for<br />
accessories drive and transmission & other losses shall be taken into<br />
account. If twin engines are supplied both the engines or either of the<br />
two engines should be capable of transmitting power either to Draw<br />
Works depending on load requirement or for road drive.<br />
NOTE: Statutory requirement for SAFETY:<br />
(i)<br />
(ii)<br />
(iii)<br />
All the rotating parts, Belts etc. should be well guarded.<br />
Engine(s) should be equipped with” Emergency Kill” devices by<br />
shutting off air supply. This device should be operative from<br />
the Driller‟s Console.<br />
Engine(s) should have two systems for self starting: (a)<br />
Electrical starting system during rig movement period and (b)<br />
Air starting system during operation period inside the well<br />
plinth.<br />
(o)<br />
(p)<br />
AIR COMPRESSOR: Air compressor of required capacity for<br />
operating Air starter for the Rig engines and other pneumatic<br />
controls. The prime mover engine of the Air compressor will be hand<br />
starting (but not electric starting). The Air compressor shall be<br />
mounted on the deck itself in a convenient position. If required, the<br />
compressor may be placed on the ground also during operation<br />
period by laying down necessary lines for air supply. The air receiver<br />
supplied should be hydraulically tested at 1.5 times the working<br />
pressure. Details of test reports should be provided along with the<br />
Rig. Also date of testing, test pressure etc should be painted on the<br />
air receiver.<br />
TRANSMISSION: May be single or double, Torque converter type<br />
automatic Transmission with minimum 3 Forward and 1 Reverse<br />
speed which is/are capable of transmitting a minimum 500 HP to the