The TR Set Local/Remote hand switch change alarm setting configures POS to alarm when<br />

control is toggled between remote and local modes.<br />

The TR Set Power changes from <strong>Precipitator</strong> by X% in Y hours alarm setting configures POS<br />

to alarm if a TR set power level drifts from the total precipitator power level in a given time frame.<br />

The TR Set Spark Rate is X% over Baseline Setpoint configures POS to alarm if a voltage<br />

control is sparking a given percentage above its spark rate set point.<br />

Individual T/R Set Alarm<br />

Click on the Individual TR Set Alarms tab to view and edit TR Set alarms. This page allows you<br />

to configure alarms for TR electrical parameters for each individual TR. They can be set the<br />

same across the precipitator or individually for each TR set. You will need to set these in each<br />

configured precipitator.<br />

Individual T/R Set Alarms Tab<br />

To set up these alarms first select the edit button. Then in the Configuration section select the<br />

alarm priority that you would like. The Set all controls equal check box allows for the settings in<br />

one control to be set identically in all controls on this precipitator. Leaving this box unchecked<br />