<strong>Precipitator</strong> <strong>Optimization</strong> <strong>System</strong> 7<br />
<strong>User</strong> <strong>Manual</strong><br />
25. Performance <strong>Optimization</strong><br />
Pressing the Performance <strong>Optimization</strong> button in the TR set or precipitator menu will open the<br />
Performance <strong>Optimization</strong> window. <strong>Optimization</strong> control is used to change power levels of<br />
selected T/R sets in relation to changes in opacity and load levels, or opacity and precipitator<br />
power levels. The program will reduce the power levels of the precipitator while monitoring<br />
opacity levels to remain in compliance with user configurable opacity limits and will reset the<br />
opacity base line to insure optimum opacity is achieved at all load or power levels.<br />
<strong>Optimization</strong> Window<br />
Performance optimization is password protected and users will need to log in before being able to<br />
start or stop optimization.<br />
Before running optimization you need to first create an optimization program and set the abort,<br />
step back and timing parameters. A basic optimization program contains a series of steps taken<br />
at specific time intervals (step time). Each step of the optimization program adjusts the voltage<br />
control’s secondary current limit to a certain percentage of the controls full-scale limit. A step can<br />
adjust any number of voltage controls on the precipitator. Limits are set on the opacity and load<br />
Copyright © 2007 <strong>Neundorfer</strong>, <strong>Inc</strong>orporated<br />