<strong>Precipitator</strong> <strong>Optimization</strong> <strong>System</strong> 7<br />

<strong>User</strong> <strong>Manual</strong><br />

The following data can be displayed on the 3D Graphs:<br />

Live Data:<br />

Primary Current - T/R sets Primary Current<br />

Primary Volts - T/R sets Primary Volts<br />

Secondary Current - T/R sets Secondary<br />

Secondary KVa - T/R sets Secondary Kilovolt A bushing<br />

Secondary KVb - T/R sets Secondary Kilovolt B bushing<br />

Primary KW - T/R sets Primary Kilowatt<br />

Secondary KW - T/R sets Secondary Kilowatt<br />

SCR Angle - SCR Conduction Angle<br />

Actual Sparks /Min - Sparks per minute<br />

Set points and limits:<br />

Sparks Sensitivity – How the control responds to sparks<br />

<strong>Optimization</strong> Percent - <strong>Optimization</strong> Percent<br />

Secondary Current Limit - Voltage Control Secondary Current Limit<br />

IE Ratio - Number of On and Off Half Cycles<br />

Primary Current Limit - Voltage Control Primary Current Limit<br />

Primary Over Volts Limit - Voltage Control Primary Over Voltage Limit<br />

Primary Under Volts Limit - Voltage Control Primary Under Voltage Limit<br />

Secondary Current Limit StPt - Secondary Current Limit Set by POS<br />

Rap Limit - Secondary Current Limit Set for Power Off or Reduced Rapping<br />

Secondary KV Limit - Voltage Control Secondary Kilovolt Limit<br />

Spark Baseline Rate - Voltage Control Sparks per minute Set Point<br />

Spark Response Mode - Voltage Control Spark Mode<br />

SCR Cond Angle Limit - Voltage Control SCR Conduction Angle Limit<br />

MVC Device Number - Voltage Control Address<br />

Back Corona Setup Code - Voltage Control Back Corona Detection Setup Code<br />

IE Ratio POS Set Point Code - IE Ratio POS Set Point Code Set by POS<br />

Full Scale Secondary Current – Voltage Control Full Scale Secondary Current in Milliamps<br />

Secondary Current Density – Ratio of Secondary Current over collecting plate size<br />

Copyright © 2007 <strong>Neundorfer</strong>, <strong>Inc</strong>orporated<br />

Specifications and Features subject to change without notice<br />

08/01/07<br />

60