Commentary on the Prescriptive Method for One and Two Family Dwellings - 2004 91<br />

F8 Ridge Tension Strap Connection Requirement<br />

Calculate the number of screws required for the ridge tension strap for a 24-foot span, 6:12<br />

pitched roof subjected to 120 mph wind speed, Exposure Category C.<br />

Calculate Wind Load<br />

Per ASCE 7-1998 (ASCE, 1998):<br />

Directionality Factor (K d )= 0.85 (Table 6-6)<br />

Importance Factor = 1.0 (Section 6.5.5)<br />

Topographic Factor (K zt )= 1.0 (Figure 6-2)<br />

Velocity Exposure (K z ) = 0.98 (Table 6-5)<br />

Velocity Pressure = q z = 0.00256 x K z x K zt x K d (V 2 x I) = 30.7077 (Eq. 6.5.10)<br />

Pressure = p = q z [(GC pf ) – (GC pi )] (Eq. 6.5.12.2.1)<br />

GC pf (Figure 6-4) CASE A<br />

Roof Slope = 26.56 degrees<br />

Area 1 Area 2 Area 3 Area 4 Area 1E Area 2E Area 3E Area 4E<br />

0.550 -0.103 -0.447 -0.391 0.727 -0.196 -0.586 -0.536<br />

GCpi (Figure 6-4) CASE A<br />

Enclosed Buildings<br />

+0.18 -0.18<br />

GCpf (Figure 6-4) CASE B<br />

Roof Slope = 26.56 degrees<br />

Are<br />

a 1<br />

Area<br />

2<br />

Area<br />

3<br />

Area<br />

4<br />

Area<br />

5<br />

Area<br />

6<br />

Area<br />

1E<br />

Area<br />

2E<br />

Area<br />

3E<br />

Area<br />

4E<br />

Area<br />

5E<br />

Area<br />

6E<br />

-0.45 -0.69 -0.37 -0.45 0.4 -0.29 -0.48 -1.07 -0.53 -0.48 0.61 -0.43<br />

p (psf) - CASE A<br />

Roof Slope = 26.56 degrees<br />

Area 1 Area 2 Area 3 Area 4 Area 1E Area 2E Area 3E Area 4E<br />

22.42 -8.70 -19.25 -17.53 27.85 -11.55 -23.52 -21.99<br />

p (psf) - CASE B<br />

Roof Slope = 26.56 degrees<br />

Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 1E Area 2E Area 3E Area 4E Area 5E Area 6E<br />

-19.35 -26.72 -16.89 -19.35 17.81 -14.43 -20.27 -38.39 -21.80 -20.27 24.26 -18.73<br />

The above are based on corner length as follows:<br />

0.4 x Building Height = 12.00 ft (height = 30.00 ft)<br />

0.1 x min. Width = 2.40 ft<br />

Not less than 3’ =<br />

3.00 ft<br />

a =<br />

3.00 ft<br />

Corner Length = 2a = 6.00 ft