68 Commentary on the Prescriptive Method for One and Two Family Dwellings - 2004<br />

12<br />

6<br />

5’ 4’ 12’ 4’ 5’<br />

9’<br />

1’<br />

3’ 6’<br />

Slab on Grade Foundation<br />

9’<br />

7’<br />

5’<br />

8’<br />

8’<br />

50’<br />

30’<br />

Sidewall Elevation<br />

Endwall Elevation<br />

Interior wall weight per square foot of floor area =<br />

@ Roof = ½(5 psf) = 2.5 psf<br />

@ Floor = ½(2)(5 psf) = 5 psf<br />

Roof weight = 15 psf(1,836 ft 2 ) = 2,7540 lb<br />

Floor weight = 10 psf(1,500 ft 2 ) = 1,5000 lb<br />

Interior walls weight = 5 psf(1,500 ft 2 ) = 7,500 lb @ Second floor<br />

= 2.5 psf(1,500 ft 2 ) = 3,750 lb @ Roof<br />

Exterior Walls (Long Walls)<br />

To Roof = (2)(50)(9)(1/2)(7) = 3,150 lb<br />

To 2 nd Floor = (2)(3,150) = 6,300 lb<br />

Exterior Walls (Short Walls)<br />

To Roof = (2)(30)(9)(1/2)(7) = 1,890 lb<br />

To 2 nd Floor = (2)(1890) = 3,780 lb<br />

Total Load at Roof = 3,150 + 1,890 = 5,040 lb<br />

Total Load at 2 nd Floor= 6,300 + 3,780 = 10,080 lb