Commentary on the Prescriptive Method for One and Two Family Dwellings - 2004 69<br />

Sum of Weights<br />

For Base Shear, Vertical Distribution and Shear Wall Design:<br />

At Roof: 27,540 + 3,750 + 5,040 = 36,330 lb<br />

At 2 nd Floor: 15,000 + 7,500 + 10,080 = 32,580 lb<br />

Sum: 36,330 + 32,580 = 68,910 lb<br />

30’<br />

P<br />

For Diaphragm Design<br />

50’<br />

P Roof = 36,330 – 3,150 = 33,180 lb<br />

P 2nd Floor = 32,580 – 6,300 = 26,280 lb<br />

30’<br />

P Roof = 36,330 – 1,890 = 34,440 lb<br />

P 2nd Floor = 32,580 – 3,780 = 28,800 lb<br />

P<br />

Determine Base Shear – SDC D2<br />

Base Shear, V = C s W (IBC Eq. 16-34)<br />

C s = S DS /R<br />

S DS = 1.17<br />

(IRC Table R301.2.2.1.1)<br />

R = 6<br />

(IBC Table 1617.6, System 1-K)<br />

C s = 1.17/6 = 0.195<br />

V = (0.195)(68,910) = 13,437 lb<br />

Vertical Distribution<br />

F x = C vx V (IBC Eq. 16-41)<br />

C vx =<br />

WxH<br />

x<br />

n<br />

(IBC Eq. 16-42 with K = 1)<br />

W H<br />

∑<br />

i<br />

i=<br />

1<br />

n<br />

∑ F i<br />

I = 1<br />

i<br />

V x = (IBC Eq. 16-43)<br />

Height 2nd = 9’ + 1’ = 10 ft<br />

Height Roof = (2)(9) + 1 + ½(7.5’) = 22.75 ft<br />

Diaphragm Weight Height Weight x Height C vx F x<br />

(lb) (ft)<br />

(lb)<br />

Roof 36,330 22.75’ 826,508 0.7173 9,638 9,638<br />

2 nd Floor 32,580 10’ 325,800 0.2827 3,799 13,437<br />

Total 68,910 1,152,308<br />

V x<br />

(lb)