Commentary on the Prescriptive Method for One and Two Family Dwellings - 2004 23<br />

F4 Framing of Openings in Roofs and Ceilings<br />

This section is similar to the openings in floors, with the maximum opening width limited<br />

to 4 feet (1.22 m).<br />

F5 Roof Trusses<br />

The Prescriptive Method does not contain provisions for trusses. This section is included so<br />

that pre-engineered trusses may be used in conjunction with this document. The Standard for<br />

Cold-Formed <strong>Steel</strong> Framing – Truss Design (AISI, 2001b) was developed to assist in the design,<br />

manufacturing and installation of steel trusses.<br />

F6 Roof Diaphragms<br />

Roof diaphragms are required to adequately transfer shear loads to the braced wall lines in a<br />

structure. In steel-framed roofs, this is typically accomplished by sheathing the roof-framing<br />

members with wood structural panels. Shear values used in the design of roof diaphragms were<br />

taken from LGSEA Technical Note No. 558b-1 (LGSEA, 1998). The values given in this<br />

document are based on the calculated strength of the fastener connection for a defined<br />

configuration with reductions in that strength taken for panel grade, panel buckling and lightly<br />

loaded diaphragms. Additional requirements for steel roof diaphragms in high wind areas (i.e., 110<br />

mph (177 km/hr) or greater wind speed) or high seismic areas (i.e., Seismic Design Category D1, D2<br />

and E) are specified in Section F6.1 and F6.2.