DICTIONARY group codes (continued)<br />

Group codes<br />

Description<br />

281 Duplicate record cloning flag (determines how to merge duplicate<br />

entries):<br />

0 = Not applicable<br />

1 = Keep existing<br />

2 = Use clone<br />

3 = $0$<br />

4 = $0$<br />

5 = Unmangle name<br />

3 Entry name (one for each entry) (optional)<br />

350 Soft-owner ID/handle to entry object (one for each entry) (optional)<br />

AutoCAD ® maintains items such as mline styles and group definitions as<br />

objects in dictionaries. The following sections describe the AutoCAD object<br />

group codes maintained in dictionaries; however, other applications are free<br />

to create and use their own dictionaries as they see fit. The prefix "ACAD_" is<br />

reserved for use by AutoCAD applications.<br />

DICTIONARYVAR<br />

The following group codes are used by DICTIONARYVAR objects. In addition<br />

to the group codes described here, see “Common Group Codes for Objects”<br />

on page 116. For information about abbreviations and formatting used in<br />

this table, see “Formatting Conventions in This Reference” on page 6.<br />

DICTIONARYVAR group codes<br />

Group codes<br />

Description<br />

0 Object name (DICTIONARYVAR)<br />

5 Handle<br />

102 Start of persistent reactors group; always “{ACAD_REACTORS”<br />

330 Soft-pointer ID/handle to owner dictionary<br />

(ACDBVARIABLEDICTIONARY)<br />

102 End of persistent reactors group, always “}”<br />

DICTIONARYVAR | 121