15 DENSITY FITTING 95<br />

15.1.2 Screening thresholds<br />

THRAO<br />

THRMO<br />

THRSW<br />

THROV<br />

THRPROD<br />

Threshold for neglecting contracted 3-index integrals in the AO<br />

basis (default 1.d-8).<br />

Threshold for neglecting half-transformed 3-index integrals (default<br />

1.d-8).<br />

Threshold for Schwarz screening (default 1.d-5).<br />

Threshold for neglecting 2-index integrals in the AO (default<br />

1.d-10.<br />

Product screening threshold for first half transformation (default<br />

1.d-8).<br />

Analogous thresholds for specfic programs can be set by appending the above keywords by the<br />

following specifications<br />

SCF<br />

COUL<br />

EXCH<br />

CPHF<br />

SCFGRD<br />

Coulomb and exchange fitting in DF-HF/DF-KS<br />

Coulomb fitting in DF-HF/DF-KS<br />

Exchange fitting in DF-HF/DF-KS<br />

Coulomb and exchange fitting in CPHF<br />

Coulomb and exchange fitting in DF-HF/DF-KS gradients<br />

The default values are the same as for the general thresholds.<br />

Further thresholds:<br />

THR2HLF<br />

THRASM SCF<br />

THRAO FOCK<br />

Threshold for second-half transformation in exchange fitting<br />

(default THRAO SCF)<br />

Threshold for local assembly of exchange matrix (default THRAO SCF)<br />

Threshold for Coulomb fitting in DF-KS<br />

(default MIN(THRAO SCF*1.d-2,1.d-12))<br />

15.1.3 Parameters to enable local fitting<br />

Local fitting as described in H.-J. Werner, F. R. Manby, and P. J. Knowles, J. Chem. Phys. 118,<br />

8149 (2003), Polly, H.-J. Werner, F. R. Manby, and Peter J. Knowles, Mol. Phys. 102, 2311<br />

(2004), and M. Schütz, H.-J. Werner, R. Lindh and F. R. Manby, J. Chem. Phys. 121, 737<br />

(2004). can be activated by setting LOCFIT=1. By default, local fitting is disabled, because<br />

under certain circumstances it can lead to unacceptable errors. For instance, local fitting must<br />

not be used in counter-poise calculations, since the lack of fitting functions at the dummy atoms<br />

can lead to wrong results.<br />

Local fitting can be restricted to certain programs, using the following options:<br />

LOCFIT<br />

LOCFIT SCF<br />

LOCFIT MP2<br />

If positive, use local fitting in all programs in which it is available<br />

(default 0).<br />

If positive, use local fitting in SCF (default LOCFIT)<br />

If positive, use local fitting in DF-LMP2; 1: use orbital domains;<br />

2: use pair domains (default LOCFIT)