19.01.2015 Views

MOLPRO

MOLPRO

MOLPRO

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

29 LOCAL CORRELATION TREATMENTS 209<br />

29.4 Summary of directives<br />

The same standard directives as in the canonical programs, e.g., OCC, CLOSED, CORE, WF,<br />

ORBITAL are also valid in the local methods. In addition, there are some directives which only<br />

apply to local calculations:<br />

LOCAL<br />

MULTP<br />

DOMAIN<br />

MERGEDOM<br />

REGION<br />

ENEPART<br />

SAVE<br />

START<br />

Invokes local methods and allows to specify the same options as on<br />

the command line.<br />

As LOCAL, but multipole approximations are used for distant pairs.<br />

Define domains manually (not recommended).<br />

Allows to merge domains<br />

Allows to select regions of a molecule to be treated at a certain level<br />

of theory.<br />

Analysis of pair energies.<br />

Save domains and LCCSD amplitudes.<br />

Restart with domains and LCCSD amplitudes from a previous calculation.<br />

29.5 General Options<br />

LOCAL=local<br />

LOCORB=option<br />

LOC METHOD=method<br />

Determines which method is used:<br />

LOCAL=0: Conventional (non-local) calculation.<br />

LOCAL=1: Local method is simulated using canonical MOs. The local<br />

basis is used only at an intermediate stage to update the amplitudes<br />

in each iteration (only for testing).<br />

LOCAL=2: Calculation is done in local basis, but without using local<br />

blocking (i.e. full matrices are used). This is the most expensive<br />

method and only for testing.<br />

LOCAL=3: Fully local calculation (obsolete).<br />

LOCAL=4: Fully local calculation (default). This is the fastest method<br />

for large molecules with many weak pairs and requires minimum<br />

memory.<br />

If this option is given and option> 0, the orbitals are localized using<br />

the Pipek-Mezey technique. If this option is not given or option=0<br />

(default), the orbitals are localized unless localized orbitals are found<br />

in the orbital record (cf. ORBITAL directive and LOCALI command).<br />

In the latter case, the most recent localized orbitals are used. Setting<br />

option=-1 switches the localization off. If option> 1 the localized<br />

orbitals are printed. Note: Boys localization can only be performed<br />

using the LOCALI command. The program will use the Boys orbitals<br />

if they are found in the orbital record and the LOCORB option is absent<br />

or option≤ 0.<br />

This option allows to select between Pipek-Mezey (method=PM) or<br />

Natural Orbitals (method=NBO) localization. If Pipek-Mezey orbitals<br />

are requested, the default Boughton-Pulay domain selection will be<br />

used. When method=NBO, the domain selection will be based on the<br />

NPA charges, with NPASEL=0.03 (by default). In both cases, the domain<br />

selection parameter can be explicitly given (cf. DOMSEL and

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!