19.01.2015 Views

MOLPRO

MOLPRO

MOLPRO

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

31 EXPLICITLY CORRELATED METHODS 242<br />

It is then more efficient to do the a DF-MP2 calculation separately and<br />

compute the total energy as the sum of the DF-MP2 energy and the<br />

F12 energy<br />

Further options for density fitting are described in section 15, and further options to choose the<br />

ansatz in section 31.7.<br />

Typical inputs for calculations with local approximations are:<br />

!parameters for local density fitting:<br />

DFIT,LOCFIT_F12=1,FITDOM_MP2=1,IDOMAUX_MP2=3,DSCREEN=1<br />

!LMP2-F12(loc) with local RI:<br />

{DF-LMP2-F12,ANSATZ=3*A(LOC),DOMSEL=0.985,RAODOM=5,PAIRS=WEAK}<br />

This would perform a local MP2 with a Boughton-Pulay domain completeness criterion of<br />

0.985. In the F12 part, distant pairs are not included (PAIRS=WEAK) and the local projector is<br />

used (USEPAO=1, default). Local density fitting and local RI approximations are used.<br />

A corresponding non-local calculation (still using localized orbitals and the diagonal ansatz)<br />

would be<br />

{DF-LMP2-F12,ANSATZ=3*A(LOC),DOMSEL=1.0,USEVRT=1,NOMP2=1}<br />

ecorr_F12=ef12<br />

{DF-MP2}<br />

ecorr_MP2=energy-energr<br />

ecorr_MP2_F12=ecorr_MP2+ecorr_F12<br />

!mp2 correlation energy<br />

!total correlation energy<br />

Note: The use of local DF and RI domains is still experimental and should be use with care!<br />

31.12 Variables set by the F12 programs<br />

The following variables are set by the F12 programs:<br />

ENERGR<br />

ENERGY<br />

ENERGC<br />

Reference energy. This includes the perturbative CABS singles correction<br />

if computed.<br />

Total energy of the requested method (including the F12 and singles<br />

corrections). ENERGY(1) and ENERGY(2) hold the F12A and<br />

F12B values, respectively (if both are computed).<br />

Total CCSD-F12 energies in ccsd-f12 or uccsd-f12 calculations. ENERGC(1)<br />

and ENERGC(2) hold the F12A and F12B values, respectively (if<br />

both are computed). The difference of ENERGY and ENERGC is the<br />

triples energy contribution.<br />

ENERGT Triples energy contribution. This is a vector. The corresponding<br />

methods are stored in METHODT (strings).<br />

EMP2<br />

EMP2 SCS<br />

Total MP2 energy (excluding F12 correction, but including the singles<br />

correction).<br />

Total SCS-MP2 energy (excluding F12 correction, but including the<br />

singles correction).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!