47 POTENTIAL ENERGY SURFACES (SURF) 354<br />

INFO=value<br />

ment. Symmetry of the modes will be determined even if the NOSYM<br />

keyword is used in the electronic structure calculations. In certain<br />

cases numerical noise can be very high and thus prohibits a correct<br />

determination of the symmetry labels. This is denoted by the label<br />

Err for these modes. In such cases symmetry should be switched off<br />

in the calculation of the potential energy surfaces and the VCI calculations,<br />

because the results may be corrupted. Symmetry can be<br />

switched off by using MPG=1.<br />

INFO=1 provides a list of the values of all relevant program parameters<br />

(options).<br />

The following example shows the input of a calculation which computes energy and dipole<br />

surfaces at the MP2/cc-pVTZ level and subsequently determines the anharmonic frequencies at<br />

the VSCF and VCI levels. Hartree-Fock calculations will not be restarted and the .log-file is<br />

directed to the scratch directory as defined by the $TMPDIR variable.<br />

memory,20,m<br />

geomtyp=xyz<br />

orient,mass<br />

geometry={<br />

3<br />

Water<br />

O 0.0675762564 0.0000000000 -1.3259214590<br />

H -0.4362118830 -0.7612267436 -1.7014971211<br />

H -0.4362118830 0.7612267436 -1.7014971211<br />

}<br />

mass,iso<br />

basis=vdz<br />

logfile,scratch<br />

hf<br />

mp2<br />

optg<br />

{frequencies,symm=auto<br />

print,low=50}<br />

label1<br />

{hf<br />

start,atden}<br />

{mp2<br />

cphf,1}<br />

surf,start1D=label1,dipole=1,sym=auto<br />

vscf,dipole=1,combi=1<br />

vci,dipole=1,version=3,combi=1<br />

47.2 Multi-level calculations<br />

VMULT,options<br />

The level of the electronic structure calculations can be changed for the different i-body terms in<br />

the expansion of the potential. As a consequence, the keywords START2D, START3D, VAR2D<br />

and VAR3D exist in full analogy to the keywords START1D and VAR1D in standard calculations<br />

(see above). The number always represents the level of the expansion term. Such calculations