248 3. Reference Manual<br />

Replace all parameters in<br />

device model equations by<br />

numerical values.<br />

In[37]:= CircuitEquations[rectifier, AnalysisMode −> Transient,<br />

ElementValues −> Symbolic, Symbolic −> None<br />

] // DisplayForm<br />

Out[37]//DisplayForm=<br />

I$AC$D1t I$V1t ⩵⩵ 0, I$AC$D1t <br />

V$2t CL V$2 ′ t ⩵⩵ 0,<br />

RL<br />

V$1t ⩵⩵ Vin, I$AC$D1t ⩵⩵<br />

1. 10 14 1 38.6635 V$1tV$2t 1. 10 12 V$1t V$2t,<br />

V$1t, V$2t, I$V1t, I$AC$D1t, DesignPoint <br />

Vin 5 Sin100 Π t, RL 1000., CL 0.000022<br />

Finally, the Symbolic option allows you to specify for each device or group of devices the parameters<br />

which CircuitEquations should keep in symbolic form.<br />

Keep only the parameters<br />

AREA and TEMP of all<br />

diode instances "D*" in<br />

symbolic form, replace all<br />

other model parameters by<br />

numerical values.<br />

Use the symbol Τ to<br />

denote time.<br />

In[38]:= CircuitEquations[rectifier,<br />

AnalysisMode −> Transient, ElementValues −> Symbolic,<br />

Symbolic −> {"D*" −> {AREA, TEMP}}] // DisplayForm<br />

Out[38]//DisplayForm=<br />

I$AC$D1t I$V1t ⩵⩵ 0,<br />

I$AC$D1t <br />

V$2t CL V$2 ′ t ⩵⩵ 0, V$1t ⩵⩵ Vin,<br />

RL<br />

I$AC$D1t ⩵⩵ 3.69815 10 22 12881.4 1.0.00333167 TEMP<br />

<br />

AREA$D1 <br />

TEMP<br />

11604.8 V$1tV$2t<br />

<br />

1 <br />

TEMP<br />

TEMP 3. 1. 10 12 V$1t V$2t,<br />

V$1t, V$2t, I$V1t, I$AC$D1t, DesignPoint <br />

Vin 5 Sin100 Π t, RL 1000.,<br />

CL 0.000022, AREA$D1 1., TEMP 300.15<br />

In[39]:= CircuitEquations[tempckt, AnalysisMode −> Transient,<br />

TimeVariable −> \[Tau]] // DisplayForm<br />

Out[39]//DisplayForm=<br />

V$1Τ V$2Τ<br />

I$V1Τ <br />

⩵⩵ 0,<br />

1 TC11 TEMP R1Τ<br />

V$2Τ<br />

<br />

1 TC12 TEMP R2Τ V$1Τ V$2Τ<br />

<br />

1 TC11 TEMP R1Τ C1 V$2′ Τ ⩵⩵ 0,<br />

V$1Τ ⩵⩵ V1, V$1Τ, V$2Τ, I$V1Τ, DesignPoint <br />

With the default settings<br />

Symbolic −> All and Value −> None, all device parameters of the diode appear in symbolic form<br />

when you set up a system of circuit equations with ElementValues −> Symbolic.