3.10 Interfaces 381<br />

WriteSimulationData has the following options:<br />

option name<br />

default value<br />

ComplexValues False whether the data should be written as<br />

complex numbers<br />

Compiled True if exprs should be compiled<br />

DataLabels Automatic list of strings to give the traces a more<br />

convenient name<br />

InterpolationOrder 1 specifies the interpolation order of the<br />

resulting interpolating functions<br />

PlotPoints 100 number of sample points<br />

Protocol<br />

Inherited[AnalogInsydes]<br />

standard Analog Insydes protocol<br />

specification (see Section 3.14.5)<br />

Sampling Linear whether to sample Linear or Exponential<br />

Simulator<br />

Options for WriteSimulationData.<br />

Inherited[AnalogInsydes]<br />

standard Analog Insydes simulator<br />

specification (see Section 3.14.6)<br />

See also: ReadSimulationData (Section 3.10.3), Simulator (Section 3.14.6).<br />

Options Description<br />

A detailed description of all WriteSimulationData options is given below in alphabetical order:<br />

ComplexValues<br />

To generate complex-valued data from a small-signal analysis set ComplexValues −> True to write<br />

the data as complex numbers.<br />

The default ComplexValues −> False writes real numbers which can be used for DC and transient<br />

analyses.<br />

Compiled<br />

With Compiled −> True the expression exprs is compiled with the Mathematica command Compile<br />

before evaluation.