3.5 Setting Up and Solving Circuit Equations 253<br />

DCEquations provides the following options:<br />

option name<br />

default value<br />

InitialTime Automatic initial time to insert into the equation and<br />

the design point<br />

ModeValues Automatic whether to extract independent source<br />

values from the ModeValues option of the<br />

DAEObject<br />

Options for DCEquations.<br />

See also: ACEquations (Section 3.5.2), CircuitEquations (Section 3.5.1).<br />

Options Description<br />

InitialTime<br />

The option InitialTime specifies the value (which can be any Mathematica expression) to be<br />

substituted for the independent variable in the equation system and the design point. If the value<br />

of the InitialTime option is set to Automatic, the initial time is extracted from the InitialTime<br />

option stored in the DAEObject. The default setting is InitialTime −> Automatic.<br />

ModeValues<br />

The option ModeValues specifies whether values of independent sources should be updated in the<br />

DesignPoint option of the returned DAEObject. If the value of the ModeValues option is set to<br />

Automatic, DC values of independent sources are extracted from the ModeValues option stored in the<br />

DAEObject. If the value of the ModeValues option is set to None, the values of independent sources<br />

are used as-is. Note that in both cases the initial time is inserted into the design-point values. The<br />

default setting is ModeValues −> Automatic.<br />