1. Fully-compact sections. The limiting values of moment for the two<br />

checks are found by employing the plastic expressions (9.22) with S p<br />

changed to S pm . Here S pm is a modified value of the plastic modulus,<br />

which takes account of the inclination of mm as well as the presence<br />

of P (Section 10.2.3).<br />

2. Semi-compact <strong>and</strong> slender sections. The applied moment is resolved<br />

into components M cos � <strong>and</strong> M sin � about the principal axes, the<br />

effects of which are superposed elastically with that of P. The section<br />

is adequate if at any critical point Q:<br />

(9.26a)<br />

(9.26b)<br />

where x, y are the coordinates of Q, <strong>and</strong> the I’s relate to the effective<br />

section. P is taken positive if tensile <strong>and</strong> negative if compressive. The<br />

left-h<strong>and</strong> side of the equation is always taken positive.<br />

9.7.8 Treatment of local buckling<br />

In applying checks A–D <strong>and</strong> E–G, care is needed in dealing with<br />

elements prone to local buckling. It was explained that the section<br />

classification is based on the simultaneous action of P <strong>and</strong> M (Section<br />

9.7.3). If on this basis the section comes out as fully or semicompact,<br />

no deduction for local buckling should be made in the<br />

determination of P c <strong>and</strong> M c for these checks, even though the section<br />

might be regarded as slender under the action of P or M in isolation.<br />

But if (under P+M) the section is found to be slender, P c <strong>and</strong> M c<br />

should be found exactly as specified in Sections 9.7.4 <strong>and</strong> 9.7.6,<br />

taking (different) effective sections each appropriate to the action<br />

considered (P or M).<br />

9.7.9 Eccentrically connected angles, channels <strong>and</strong> tees<br />

Axial members of angle, channel or tee-section are often connected to<br />

one side of a gusset-plate at their ends. Such members are subject to<br />

end moment as well as axial force, because of the eccentricity of loading,<br />

<strong>and</strong> may be rigorously checked using the appropriate interaction<br />

equations. Alternatively, an easier method can be adopted as follows<br />

without too severe loss of accuracy (based on BS.8118). The procedure<br />

is to treat the member as an ordinary tie or strut, <strong>and</strong> make a simple<br />

correction to allow for the eccentricity as follows:<br />