02.07.2015 Views

PK-232 MBX Operating Manual - N3UJJ

PK-232 MBX Operating Manual - N3UJJ

PK-232 MBX Operating Manual - N3UJJ

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PK</strong>-<strong>232</strong> OPERATING MANUAL<br />

COMMAND SUMMARY<br />

A.1 Introduction<br />

APPENDIX A<br />

COMMAND SUMMARY<br />

Your <strong>PK</strong>-<strong>232</strong> is controlled by Commands that you enter from the keyboard.<br />

Most of these commands have a standard (default) value that provides good<br />

performance. There are a few commands that you will need to change. This<br />

section is intended as a command and error message reference and is not<br />

meant to be read from start to finish.<br />

A.1.1<br />

Entering Commands<br />

Timewave Software for the <strong>PK</strong>-<strong>232</strong> such as PC-PAKRATT has menus and even online<br />

help for commands. If you are using a Timewave program, please<br />

consult the Program manual for instructions on entering commands. The<br />

instructions below assume you are using a terminal or terminal-emulating<br />

program on your personal computer.<br />

Most Commands are short names for the instruction you want the <strong>PK</strong>-<strong>232</strong> to<br />

perform. Commands are entered after the Command prompt "Cmd:".<br />

• You may use either UPPER or lower case when entering commands.<br />

• End the command with a carriage return or the key.<br />

• Correct any typing mistakes before typing the final .<br />

A.1.2<br />

Command Responses<br />

Whenever the <strong>PK</strong>-<strong>232</strong> accepts a command it responds by displaying both the<br />

old and new values. For example, if you type "XFLOW OFF" - you'll see the<br />

display:<br />

XFlow was ON<br />

XFlow now OFF<br />

This message tells you that the value has been changed successfully.<br />

A.2 Command List<br />

Commands are listed alphabetically in the following command<br />

descriptions. Each command entry contains several sections:<br />

Command Name, Default Value, Mode(s) in which the command is used,<br />

HOST mode abbreviation (for HOST mode programmers), and Parameters<br />

A.2.1<br />

Command Names and Abbreviations<br />

The command name at the beginning of the description is the full word<br />

you can type in order to have your <strong>PK</strong>-<strong>232</strong> execute this command. The<br />

capital letters indicate the minimum abbreviation you can use instead<br />

of the full word. For example:<br />

You can enter the command MYCALL by simply typing "MY". (Note: DO NOT<br />

type the "quotation marks") The abbreviation "M" is not sufficient,<br />

but "MY”, “MYC”, "MYCA”, “MYCAL” or "MYCALL" are all acceptable.<br />

4/91 A-1<br />

From The <strong>N3UJJ</strong>.COM Document Library

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!