_______________________________________________________________________________<br />

MDCheck<br />

Immediate Command<br />

Mode: AMTOR Packet/MailDrop<br />

Host: M1<br />

_______________________________________________________________________________<br />

MDCHECK is an immediate command which allows you to log on to your own MailDrop.<br />

After logging on, you can EDIT, LIST, READ, SEND or KILL MailDrop messages.<br />

To use the MDCHECK command, and your <strong>PK</strong>-<strong>232</strong> must not be connected to or linked<br />

to any packet or AMTOR stations. For monitoring purposes, local access of the<br />

MailDrop is considered a connection. Type "B" (BYE) to quit local control of<br />

your MailDrop.<br />

_______________________________________________________________________________<br />

MDigi ON|OFF<br />

Default: OFF<br />

Mode: Packet<br />

Host: MD<br />

_________________________________ Parameters: _________________________________<br />

ON - I and UI frames having your call sign (MYCALL or MYALIAS) as the next<br />

digipeater in the field are displayed, regardless of connected status.<br />

OFF - Normal monitoring as determined by the monitoring mode commands.<br />

_______________________________________________________________________________<br />

MDIGI permits you to display packets when another station uses your station as a<br />

digipeater. If you want to monitor ALL traffic that flows through your packet<br />

station, set MDIGI ON.<br />

You may not want to see all the data passing through your station, especially if<br />

many others use you as a digipeater. In this case set MDIGI OFF (default).<br />

_______________________________________________________________________________<br />

MDMon ON|OFF<br />

Default: OFF<br />

Mode: AMTOR and Packet/MailDrop<br />

Host: Mm<br />

_________________________________ Parameters: _________________________________<br />

ON - Monitor a calling station's activity on your MailDrop.<br />

OFF - Normal monitoring as determined by the monitoring mode commands.<br />

_______________________________________________________________________________<br />

Set MDMON to ON to monitor activity on your MailDrop.<br />

MDMON permits you to monitor activity on your AMTOR or packet MailDrop showing<br />

you both sides of the QSO. Packet headers are not shown while a caller is<br />

logged on. When no one is connected to your MailDrop, channel activity is<br />

monitored according to the setting of MONITOR.<br />

Set MDMON OFF to cancel MailDrop monitoring. Note that MailDrop connect and<br />

link status messages will be displayed even with MDMON OFF. These status<br />

messages are important and allow you to see who is connected to your MailDrop.<br />

They can be disabled however with the UBIT 13 command. See the UBIT command for<br />

more information .<br />