<strong>PathFinder</strong> Version 4.22 User <strong>Guide</strong>On On the the third second form, form,click click Create OK to to accept make thea authorisations.set of new blankdatabase tables. If awarning promptappears at this stage,click Yes.From the pull-down menus, select Settings | Options. The dialogue box below will now bedisplayed:At this stage, it is important to set:• No. Of Ports. This should match the number of ports currently equipped on the matrix. Ifthis changes in the future when the system is expanded, the value should be increasedaccordingly.• Controller Card Type must be set correctly or <strong>PathFinder</strong> will not communicate with thematrix. Check the system order paperwork or examine the 500-02 Talkback Controller.PC Adapter Card Address must be set to match the hardware address of the PC link adaptercard. Further information is given in the Commander Installation <strong>Guide</strong>.Page 16 of 16 Issue 1 <strong>Trilogy</strong> <strong>Communications</strong> Limited