<strong>PathFinder</strong> Version 4.22 User <strong>Guide</strong>15.1.4.1 Programming Logic Inputs to trigger panel 4-wire callingFollow this sequence:• Select the Inputs radio button on the logic page• Select the 4 Wire Port field on the required logic input.• Right click on this field to view the 4-wire port list pop-up and select the 4 wire port inputrequired.• Click the tick box to accept the edit.Note: There are two versions of 4 wire calling available in the Commander system:• Non-persistent 4-wire call flashes the panel yellow tally whilst the logic input is made:removing the logic input cancels the tally flash.• Persistent 4-wire call flashes the panel yellow tally when the logic input is made. Onremoving the logic input, the tally remains flashing until one of the panels in the systemanswers the call, thus clearing down the tallies on all panels receiving the call.The 4-wire call persistence mode is set from the Options | Settings | Operation menu. Tickthe 4 wire persistence check box to set 4-wire call persistence mode.Page 88 of 88 Issue 1 <strong>Trilogy</strong> <strong>Communications</strong> Limited