12.07.2015 Views

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical RequirementsSand Filter<strong>Design</strong> Criteria<strong>Design</strong> criteria for the Austin Sand Filter are listed in Table SF-1. Use the <strong>Design</strong> Data Summary Sheetprovided at the end <strong>of</strong> this fact sheet (Table SF-3) to record design information for the permittingagency’s review.Table SF-1. Austin Sand Filter <strong>Design</strong> Criteria<strong>Design</strong> Parameter Criteria NotesSedimentation BasinMaximum tributary drainage area 50 acres The larger the tributary area, the larger the surface area<strong>of</strong> filter required.Minimum basin volume WQV See Appendix E in this <strong>Design</strong> <strong>Manual</strong>Minimum/Maximum basin water depth (d SB ) 3ft/10 ftMinimum length/width ratio 2:1Maximum drawdown time 48 hrs Based on WQV (See Appendix E)Freeboard 1 ft Above maximum water surface elevationMaximum inlet velocity 3 ft/sec Provide inlet energy dissipater as required to limit inletvelocity to 3 ft/secFiltration BasinMinimum gravel depth over sand filter (ifapplicable)2 in. See Figures SF-3 and 4Minimum storage volume above filter bed 20% Based on WQVMinimum storage depth above filter bed (d s )3 ftMinimum sand depth in filter bed (d f ) 18 in. Place geotextile fabric between sand and gravel layersCoefficient <strong>of</strong> permeability for sand filter (k) 3.5 ft/day 0.146 ft/hourSand size, diameter0.02-0.04 in.Slope <strong>of</strong> sand filter surface 0% flatMinimum gravel cover over underdrain 2 in. Gravel not required under the drain pipeUnderdrain gravel size, diameter0.5-2 in.Minimum inside diameter <strong>of</strong> underdrain6 in.Underdrain pipe type PVC Schedule 40 (or heavier)Minimum slope <strong>of</strong> underdrain 1%Minimum underdrain perforation, diameter 0.375 in. 3/8 inchMinimum perforations per row 6Minimum space between perforation rows6 in.Maximum drawdown time (t f )48 hrsMinimum gravel bed depth, (d g )16 in.Liner (if required)Clay<strong>Stormwater</strong> <strong>Quality</strong> <strong>Design</strong> <strong>Manual</strong> for the <strong>Sacramento</strong> and South Placer Regions<strong>May</strong> <strong>2007</strong>SF-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!