Run<strong>of</strong>f Reduction Fact SheetDisconnected Ro<strong>of</strong> DrainsTable DRD-2. <strong>Design</strong> Criteria for Disconnected Ro<strong>of</strong> DrainsAlso see Appendix D for information on calculating run<strong>of</strong>f reduction credits.Variation/Parameter CriteriaSplash Block/Pop-up Drainage EmitterSurfaceSplash BlockSpreaderEmitter/pipeMinimum 2% positive slope away from building foundations for 4 feet minimum.Surface must be contoured to allow for sheet flow at least 5 feet wide. Must beplanted with erosion resistant vegetation (turf or dense groundcover). Ground coveruse limited to slopes less than 4%.Must be at least 24 inches long, 2 inches deep and 10-12 inches wide where itmeets the conveyance zone. Must weigh at least 10 pounds and be sloped awayfrom building.Where slope more than 8%, spreader required at end <strong>of</strong> splash block; spreadermust be drain rock, 24 inches long, 6 inches wide, and 8 inches deep, and level atsurface. Gravel may be placed below surface and covered with geotextile fabric, 4inches <strong>of</strong> soil and grass.Pipe must be at least 6 inches below the surface and a minimum <strong>of</strong> 4 inches indiameter (may not be suitable for large contributing ro<strong>of</strong> areas). Emitter elevationmust be lower than the finished grade <strong>of</strong> the base <strong>of</strong> the downspout and the yarddrain (if used). Emitter must daylight no less than 5 feet from building (residentialonly).Travel Distance See Table DRD-1 and Appendix D.Dispersal Trench and Dry WellSoilsPretreatment SumpOverflowLoadingSurfaceDispersal Trench onlySetbackSoil type extending 3 feet from bottom <strong>of</strong> facility must have infiltration rate between0.52 inches per hour and 8.27 inches per hour. Soil may be amended to achieveinfiltration rate.Must be located a minimum <strong>of</strong> 5 feet from building. Must be labeled at surface“clean-out sump for dispersal trench or dry well”.Must be set on splash block.Must demonstrate that the appropriate loading tolerance is achieved for proposeduse <strong>of</strong> surface. Provide psi rating for structure/design.Minimum 2% positive slope away from building foundations (4 feet minimum) (perBuilding Code).Must be located a minimum <strong>of</strong> 20 feet from building. A smaller setback maybeallowed with geotechnical engineer approval.Configuration Must be installed parallel to site contours; must be a minimum <strong>of</strong> 2 feet wide and 18inches deep; must be a minimum <strong>of</strong> 8 feet long; must be lined with geotextile fabric(sides and top) and filled with drain rock.Surface LabelPerforated PipeSurface identification label may be required; check with the local permitting agency.Must be a minimum <strong>of</strong> 6 inches below grade.<strong>Stormwater</strong> <strong>Quality</strong> <strong>Design</strong> <strong>Manual</strong> for the <strong>Sacramento</strong> and South Placer Regions<strong>May</strong> <strong>2007</strong>DRD-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!