12.07.2015 Views

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

Stormwater Quality Design Manual (May 2007) - City of Sacramento ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical RequirementsSand FilterStep 4 – <strong>Design</strong> Filter BedThe sand filter bed may be either <strong>of</strong> the two configurations given below. Sand bed depths are final,consolidated depths, so consolidation effects must be taken into account.a. Sand Bed with Gravel Underdrain (Figure SF-3)The sand layer shall be a minimum depth <strong>of</strong> 18 inches and shall consist <strong>of</strong> 0.02 to 0.04-inchdiameter sand. Below the sand is a layer <strong>of</strong> 0.5 to 2-inch diameter gravel that provides aminimum <strong>of</strong> two (2) inches <strong>of</strong> cover over the top <strong>of</strong> the underdrain lateral pipes. No gravel isrequired under the lateral pipes. A layer <strong>of</strong> geotextile fabric meeting the specifications in TableSF-2 must separate the sand and gravel and must be wrapped around the lateral pipes.Drainage matting meeting the specifications in Table SF-2 should be placed under the laterals toprovide for adequate vertical and horizontal hydraulic conductivity to the laterals.In areas with expected high sediment loads (total suspended solids concentration ≥ 200 mg/L),the two-inch layer <strong>of</strong> gravel on top <strong>of</strong> the sand filter should be underlain with Enkadrain 9120filter fabric or equivalent meeting the specifications in Table SF-2.b. Sand Bed with Trench Underdrain (Figure SF-4)The top layer shall be 12-18 inches <strong>of</strong> 0.02 to 0.04-inch diameter sand. Laterals shall be placed intrenches with a covering <strong>of</strong> 0.5 to 2-inch gravel and geotextile fabric (see Table SF-2). Thelaterals shall be underlain by a layer <strong>of</strong> drainage matting (see Table SF-2).In areas with expected high sediment loads, see the note above about use <strong>of</strong> Enkadrain filterfabric or equivalent.Step 5 – <strong>Design</strong> Underdrain PipingThe underdrain piping consists <strong>of</strong> the main collector pipe(s) and perforated lateral branch pipes (see planview in Figure SF-1). The piping should be reinforced to withstand the weight <strong>of</strong> the overburden. Internaldiameters <strong>of</strong> lateral branch pipes should be six inches or greater and perforations should be 3/8 inch. Eachrow <strong>of</strong> perforations should contain at least six holes and the maximum spacing between rows <strong>of</strong>perforations should not exceed six inches. All piping is to be Schedule 40 polyvinyl chloride (PVC) orgreater strength. The minimum slope <strong>of</strong> piping shall be 1/8 inch per foot (one (1) percent; slopes down toone-half (0.5) percent may be acceptable to the permitting agency). Access for cleaning all underdrainpiping is needed.Note: Unlike the sedimentation basin, the filtration basin does not require a drawdown time for release.Thus, it is not necessary to have a specifically-designed orifice for the filtration basin outlet structure.Step 6 – <strong>Design</strong> Filtration Basin LinerIf the filtration basin is an earthen structure and an impermeable liner is required to protect groundwaterquality, the liner shall provide a maximum permeability <strong>of</strong> 1x10 -6 cm/sec (ASTM Method D-2434). If animpermeable liner is not required, then install a geotextile fabric liner that meets the specifications listedin Table SF-3 unless the basin has been excavated to bedrock.<strong>Stormwater</strong> <strong>Quality</strong> <strong>Design</strong> <strong>Manual</strong> for the <strong>Sacramento</strong> and South Placer RegionsSF-8 <strong>May</strong> <strong>2007</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!