<strong>SP</strong>-<strong>2000</strong>/X-YMaintenance And RepairTarget Sensor CalibrationThe calibration pots and indicators for the sensors are on the Dolly Board. TheDolly Board is mounted on the West side of the pedestal and is visible throughthe removable window in the North cover. Each sensor assembly contains threeindividual sensors, each with its own calibration pot on the Dolly Board.Dolly Board WindowThe window allows you to monitor the sensor status during targeting and calibratethe sensors without removing the covers. Errors during targeting are anindication that sensor calibration and/or cleaning may be necessary. If the redERR LED flashes after targeting, this indicates that one or more sensors areincorrectly set. In normal operating mode, the “light meter” LEDs are used asindividual sensor indicators as marked on the board. Therefore, one or more ofthese LEDs will be on to indicate which sensor(s) need calibration.Dolly BoardLEDsSW1SW2Calibration Pots4-26 User Manual