Design and functionMIG/MAG welding5.9.19 Advanced settingsThe special parameters cannot be viewed directly since they are normally only set and stored once. Themachine control offers the following special functions:5.9.19.1 Selecting, changing and saving parameters0lAMPVOLTPROGHOLDm/minm/minFigure 5-37NOTEENTER (Enter the menu)• Switch off machine at the main switch.• Press and hold the "left parameter selection" button and switch the machine on again at thesame time.NAVIGATION (Navigate the menu)• Select parameters by turning the "welding parameter setting" rotary dial.• Set or change the parameters by turning the "arc length correction/select welding program"rotary dial.EXIT (Exit the menu)• Press the "right parameter selection" button (switch machine off and on again).099-005234-EW50116.04.201269