12.07.2015 Views

Operating instructions - EWM Hightec Welding GmbH

Operating instructions - EWM Hightec Welding GmbH

Operating instructions - EWM Hightec Welding GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical dataPhoenix 401 Concept puls FKG8 Technical dataNOTEPerformance specifications and guarantee only in connection with original spare andreplacement parts!8.1 Phoenix 401 Concept puls FKGSetting range for welding current/voltage:TIG5 A/10.2 V to 400 A/26.0 VMMA5 A/20.2 V to 400 A/36.0 VMIG/MAG5 A/14.3 V to 400 A/34.0 VDuty cycle at 25 °C80% 400 A100% 390 ADuty cycle at 40 °C60% 400 A100% 360 ALoad alternation10 min. (60% DC ∧ 6 min. welding, 4 min. pause)Open circuit voltage79 VMains voltage (tolerances) 3 x 400 V (-25% to +20%)Frequency50/60 HzMains fuse (safety fuse, slow-blow)3 x 35 AMains connection leadH07RN-F4G4Maximum connected loadMIG/MAG17.2 kVATIG13.1 kVAMMA18.2 kVARecommended generator rating25.0 kVAcosϕ 0.99Insulation class/protection classification H/IP 23Ambient temperature -20 °C to +40 °CMachine/torch coolingFan/gas<strong>Welding</strong> lead70 mm²Dimensions L x W x H in mm 1100 x 455 x 950Weight105 kgWire feed speed0.5 m/min to 24 m/minStandard roller installation1.0 mm + 1.2 mm (for steel wire)Drive type4-roller (37 mm)<strong>Welding</strong> torch connectionEuro torch connectorEMC classAConstructed to standards IEC 60974-1, -5, -10/099-005234-EW50116.04.201297

Hooray! Your file is uploaded and ready to be published.

Saved successfully!