PC Automatic TestsThe system warns you and the test restarts if:— Low flow is detected,or— Minimum diluti<strong>on</strong> requirements are not metor— RPM values are outside the range for more than two c<strong>on</strong>secutivesec<strong>on</strong>ds (or the time set in Time Allowed Outside RPM Range) or atotal of ten sec<strong>on</strong>ds (or the number set in Total Time Allowed OutsideRPM Range).Pass/FailFGA allows a maximum of three restarts (or the number set in MaxRestarts). A fourth restart (or the number in Max Restarts+1) causes theTSI Test to abort.✓ Select the Tachometer butt<strong>on</strong> at any time to rec<strong>on</strong>figure thetachometer. The test then restarts.✓ Press the Abort butt<strong>on</strong> at any time to stop the test.When the TSI Test ends, FGA proceeds to test completi<strong>on</strong>, discussed inTest Completed, page 3D-6.Test Completed13. When the TSI Simulati<strong>on</strong> is complete, the Test Completed windowdisplays.Figure 3D-6: Test Completed Screen14. Remove the tachometer lead and sample probe from the vehicle.15. Press OK.3D-6