Operating Instructions - Snap-on Equipment

Operating Instructions - Snap-on Equipment

Operating Instructions - Snap-on Equipment

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Pocket PC MaintenanceLow Out FlowThis message displays when the bench/gas analyzer exhaust out hose isplugged or disc<strong>on</strong>nected and the pump turns off. Correct the problem andturn <strong>on</strong> the pump.Low In FlowThe gas analyzer senses when the inlet sample hose is plugged. If thescreen indicates low flow, you must clear the hose to enable furthertesting. If low flow persists and the source of the low flow cannot be found,locate the quick disc<strong>on</strong>nect <strong>on</strong> the hose leaving the water filter bowl (thisfitting has a red ring above the hose) and remove the c<strong>on</strong>necti<strong>on</strong>. Pushupward <strong>on</strong> the red ring and pull the hose out. Wait ten sec<strong>on</strong>ds andrec<strong>on</strong>nect.If excessive water accumulates in the bowl the analyzer indicates LOW INFLOW. The filter bowl has a float located inside to protect the analyzerbench. Empty the water from the filter bowl and change the filter. SeeWater Trap / Filter Maintenance Warnings, page 2G-26. Then, locate thequick disc<strong>on</strong>nect <strong>on</strong> the hose leaving the water filter bowl (this fitting has ared ring above the hose) and remove the c<strong>on</strong>necti<strong>on</strong>. Push upward <strong>on</strong> thered ring and pull the hose out. Wait ten sec<strong>on</strong>ds and rec<strong>on</strong>nect.Low flow may occur when operating the analyzer upside down or when theanalyzer is sitting <strong>on</strong> a severe incline.NO x Cell Low VoltageThis message could appear at the end of a gas calibrati<strong>on</strong> and indicatesthe NO x cell may need to be replaced.✓ If this message appears, perform gas calibrati<strong>on</strong> again using theNew NO x Cell Calibrated procedure in place of the standard gascalibrati<strong>on</strong>. (Maintenance > Setup > New NO x )Pump OffThe FGA software provides the ability to toggle the gas bench pump Onand Off. From the Main menu select Meters / Graph and then Pump to turnthe pump <strong>on</strong> or off. Normally, the pump turns <strong>on</strong> automatically any timeyou enter TSI, Idle, Meters, Strip Chart or Bar Graph. If you see the PumpOff message, it means an error has caused the pump to turn off. Exit thescreen you are <strong>on</strong> and re-enter to turn the pump back <strong>on</strong>.Excess Diluti<strong>on</strong>An Excessive Diluti<strong>on</strong> Error is caused when the software does not senseenough emissi<strong>on</strong>s from the analyzer bench. Normally this means theprobe is not in the vehicle’s exhaust pipe or there is a hole in the exhaustpipe.The level of diluti<strong>on</strong> checked for by the software can be altered in theMinimum Diluti<strong>on</strong> field of General Setup (Main menu > Maintenance >Setup > General Setup). Diluti<strong>on</strong> value is measured by calculating CO +CO 2 . If CO + CO 2 is less than the setting in the Minimum Diluti<strong>on</strong> field, thenFGA signals the error.2G-29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!