General MaintenanceWhen FGA software senses that the internal battery voltage is insufficient, itautomatically displays a warning message:Figure 4-6: Battery Insufficient Message<strong>Equipment</strong> Guidelinesand Safety Precauti<strong>on</strong>sThe following guidelines for testing with FGA help assure accurate results andincrease the life of the equipment.• The pocket PC is a battery-powered device. When the power cable for thepocket PC is plugged into the analyzer, the pocket PC is also powered from theanalyzer. When fully charged, the battery should last about 2 hours. This timemay vary depending <strong>on</strong> the operati<strong>on</strong>s being performed. Immediately after usingthe pocket PC, return it to the charging base so the unit is charged and ready togo for the next test.✓ Hint: Always keep the pocket PC in the charging base and the chargingbase plugged in when not in use or when storing for l<strong>on</strong>g periods of time.✓ To extend FGA power, do not c<strong>on</strong>nect the pocket PC power cable to theFGA. The pocket PC must be fully charged.✓ Hint: At low temperatures, less than 40° F (4° C), you should not chargethe pocket PC from the analyzer during analyzer warm-up. Doing so maydelay warm-up.• The pocket PC display can become scratched or dirty through use in a dirtyenvir<strong>on</strong>ment. It is best to use a screen display protector when using the unit.Also, keep the unit clean and free of grease and dirt.• When using the gas analyzer indoors, always make sure there is properventilati<strong>on</strong>. The gas analyzer exhausts the same c<strong>on</strong>centrati<strong>on</strong>s as the vehiclesexhaust and a vehicle exhaust c<strong>on</strong>tains gases that may cause suffocati<strong>on</strong> ordeath.✓ Use the short exhaust hose indoors, the l<strong>on</strong>g hose when in a vehicle. Theunit will not functi<strong>on</strong> without a hose c<strong>on</strong>nected.• Observe extreme care when inserting the gas measurement probe becausecomp<strong>on</strong>ents of the vehicles exhaust or the probe itself may be very hot. Do nottouch the exposed metal surfaces of the exhaust probe when it has been in thevehicle’s exhaust.• Make sure the engine of the vehicle is warm and in good operating c<strong>on</strong>diti<strong>on</strong>before running the gas analyzer tests. A cold vehicle may produce excessexhaust gas.4-11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!