Pocket PC Meters/GraphFigure 2C-3: Strip Chart Screen✓ The first four items chosen in the Display Setup Order list are graphed. Tograph other informati<strong>on</strong>, use Display Setup and reorder your choices. SeeDisplay Setup, page 2C-6.Start Recording—Press the Start Recording butt<strong>on</strong> to begin recording aset of readings over a time span. During recording, the Start Recordingbutt<strong>on</strong> becomes the Stop Recording butt<strong>on</strong>. Press Stop Recording to endthe recording.To view the results go to the FGA main screen or Meters/Graph screenand choose Results. See Results, page 2C-9.Freeze—Press the Freeze butt<strong>on</strong> to stop the display and freeze a singleset of values for viewing. After the display is stopped, the Freeze butt<strong>on</strong>becomes the Resume butt<strong>on</strong>. Press Resume to reactivate the changingmeters display.Pump—Press to toggle the sample pump <strong>on</strong>/off when in the Meters,Graph or Bar Chart screens. The pump can also be c<strong>on</strong>trolled <strong>on</strong> Meters,Strip Chart and Graph screens by selecting the butt<strong>on</strong> displayed.Back Arrow—Returns you to the Meters / Graph menu.2C-4