d) Corridors must be at least 1.8m wide <strong>and</strong> be provided with a h<strong>and</strong> railing along the length of at leas<strong>to</strong>ne wall.e) All corridors, staircases, steps <strong>and</strong> ramps must be adequately eliminated <strong>and</strong> fitted with effectiveramps.3.5 Toilet <strong>and</strong> ablution facilitiesAdequate <strong>and</strong> accessible <strong>to</strong>ilet, bathing <strong>and</strong> washing facilities must be provided <strong>to</strong> meet the needsof service users.a) At least one <strong>to</strong>ilet <strong>and</strong> one bath must be provided for at least every 8 (eight) service users on thepremises 1:8. Where suitably adapted en-suite <strong>to</strong>ilet <strong>and</strong> bathing/shower are provided in the user’srooms, these rooms can be excluded from the calculation. The <strong>to</strong>ilet facilities should be designed foruse by one person at a time.b) Each service user must have a <strong>to</strong>ilet within close proximity of his/her private accommodation.c) Additional <strong>to</strong>ilet facilities must be provided on the premises, accessible <strong>and</strong> clearly marked next <strong>to</strong> thelounge <strong>and</strong> dining areas for use by service users.d) In calculating the number of <strong>to</strong>ilets, no account must be taken of any <strong>to</strong>ilet contained in a bathroom.e) Every <strong>to</strong>ilet must be equipped with an adequate flushing system <strong>and</strong> all <strong>to</strong>ilets, bathrooms or showersmust be maintained in good working order.f) All <strong>to</strong>ilets must be kept clean at all times, floors scrubbed <strong>and</strong> bowls cleaned <strong>and</strong> disinfected daily.g) Adequate <strong>and</strong> accessible <strong>to</strong>ilet, wash-up <strong>and</strong> bath facilities must be provided for staff membersemployed on the premises.h) One <strong>to</strong>ilet <strong>and</strong> bath or shower must be provided for at least every 12 (twelve) nursing staff, domesticstaff <strong>and</strong> other employees on the premises 1:12.i) Floors of the bathroom <strong>and</strong> <strong>to</strong>ilet facilities must be constructed of non-slippery surface.j) All bathrooms must be fitted with porcelain, enamel or cast iron enamel baths with a constant supplyof cold <strong>and</strong> hot running potable water.k) Walls of the <strong>to</strong>ilet facilities must be constructed of a smooth surface <strong>and</strong> be light coloured.l) Toilet facilities must be adequately illuminated <strong>and</strong> ventilated.m) Separate <strong>to</strong>ilet facilities <strong>and</strong> h<strong>and</strong> wash basin must be provided on the premises, for visi<strong>to</strong>rs.n) Separate bathrooms <strong>and</strong> <strong>to</strong>ilets must be provided for domestic <strong>and</strong> residential staff. The bathroomsmust be fitted with porcelain enamel or cast-iron enamel baths with a supply of hot <strong>and</strong> cold runningwater.o) One <strong>to</strong>ilet must be provided for at least every 12 members of staff, ratio 1:12.p) One bathroom or shower must be provided for at least every 12 members of staff, ratio 1:12. Incalculating the number of <strong>to</strong>ilets for staff members, no account must be taken of any <strong>to</strong>ilet contain in abathroom.q) Every <strong>to</strong>ilet must be equipped with an adequate flushing system maintained in proper workingcondition.r) Bathrooms <strong>and</strong> <strong>to</strong>ilets must be designated for each sex.3.6 Staff facilitiesa) Work station for staff members must be equipped with h<strong>and</strong> wash basins, with a supply of cold <strong>and</strong>hot running water <strong>to</strong> prevent cross infection.b) Separate <strong>to</strong>ilet facilities must be provided for staff members on the premises.3.7 Examination roomsa) A h<strong>and</strong> wash basin with a supply of cold <strong>and</strong> hot running water must be available in all examinationrooms.b) Floors must be constructed of a non-slippery floor <strong>to</strong> prevent accidental slipping.c) Walls must be painted with a light coloured washable paint.d) The examination room should be adequately equipped for first aid <strong>and</strong> emergency situations.3.8 Sluice roomsa) A minimum floor area of 7.5m2 <strong>and</strong> a minimum width of 2.5m must be available in every sluice room.DOH. <strong>Norms</strong> <strong>and</strong> st<strong>and</strong>ards for environmental health in South Africa Feb 2013 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!