BRIDGE REPAIR/REHABILITATION FEASIBILITY STUDY
Bridge Repair_Rehabilitation Feasibility Study - Town to Chatham
Bridge Repair_Rehabilitation Feasibility Study - Town to Chatham
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Visual Impacts: Replacement of the existing lifting beam using a slightly longer and larger beam<br />
section would not likely introduce a visual impact.<br />
4.3.3 Diaphragms/Cross Frames:<br />
NBIS Condition Rating: 6 (Satisfactory)<br />
Condition Description: The midspan timber blocking (diaphragms) between the stringers have<br />
worked loose and rotated in several locations throughout the bridge. Much of the preservatives<br />
have leeched from the surfaces of the timber blocking, thus increasing the risk of surface decay.<br />
However, as the timber wearing surface and structural deck generally minimizes the amount of<br />
moisture to the timber blocking needed to support fungal decay, the risk is currently low.<br />
Repair Scope: In-place preservative treatment of the timber blocking is not recommended for<br />
the same reasons it is not recommended for the timber stringers. As such, the timber blocking<br />
should be replaced similar to that recommended for the timber stringers (see 4.3.1 above).<br />
Rehabilitation Scope: As it may be necessary to modify the stringer spacing in conjunction with<br />
new crash tested timber railing, it may also be necessary to replace some or all of the timber<br />
blocking (diaphragms) to accommodate these modifications and to install additional diaphragms<br />
at the location of the traffic railing posts.<br />
Functionality and Safety: The timber blocking has no significant impact on functionality and<br />
safety.<br />
Load Capacity: The timber blocking does not contribute directly to the load carrying capacity of<br />
the bridge, but is required to brace the timber stringers and thus are considered in the rating of<br />
the stringers. The condition of the timber blocking does not significantly reduce the load<br />
capacity of the stringers.<br />
Maintenance: See 4.3.1 for similar comments regarding maintenance.<br />
Visual Impacts: See 4.3.1 for similar comments regarding visual impacts.<br />
4.3.4 King Posts (Timber Sheave Pole)<br />
NBIS Condition Rating: 6 (Satisfactory)<br />
Condition Description: The timber masts supporting the deflector sheave for the operating<br />
equipment are generally sound, but typically contain significant checks up to 1/4” in width and 4<br />
feet long. The large splits and checks are of a depth that permits fungal spores to access the<br />
center of the member where there are no preservatives, which increases the risk for decay. Much<br />
of the preservatives have leeched from the surfaces of the masts increasing the risk of surface<br />
decay as well. As the masts are vertical members, the exterior surfaces generally do not readily<br />
retain moisture.<br />
Repair/Rehab. Feasibility Study March 10, 2011<br />
Bridge No. C-07-001 (437) 27 Final Report