166 Ventilation and air conditioning<br />

25. How can an off-peak ice-making chiller be more efficient to operate than a daytime water<br />

chiller?<br />

1. Greater temperature difference between evaporation and condensing temperatures.<br />

2. Lower outdoor night-time dry- and wet-bulb air temperatures.<br />

3. Reduced electrical tariff.<br />

4. Reduces peak hours electrical demand kW.<br />

5. It is not more energy-efficient.<br />

26. Which of these can affect asthma sufferers?<br />

1. Excess of outside air ventilation.<br />

2. House dust mites and mould spores.<br />

3. Warm indoor air.<br />

4. Humid and warm indoor air.<br />

5. Matters other than those related to ventilation.<br />

27. Which is the most efficient way of recovering energy from room air?<br />

1. Recirculation.<br />

2. Sensible heat recovery thermal wheel.<br />

3. Total heat recovery thermal wheel.<br />

4. Plate heat exchanger.<br />

5. Run-around pipe coils.<br />

28. How does a run-around pipe coil system function?<br />

1. Closed pipe loop passes water by gravity circulation between heat source and sink<br />

locations.<br />

2. Outgoing air-duct water-cooled coil; closed cycle water pipework; warmed water<br />

pumped through incoming outdoor air-duct coil, recovering useful heat.<br />

3. Refrigerated evaporator coil in outgoing waste heat duct passes useful heat to<br />

condenser coil in the incoming air duct.<br />

4. Refrigeration system recovers waste heat in an outgoing air with a chilled-water coil in<br />

exhaust air duct.<br />

5. Cold-water feed pipe to domestic hot-water system preheated in an outdoor air coil in<br />

warm weather.<br />

29. What does a chilled beam mean?<br />

1. Steel structural beam exposed in the occupied room and cooled by a supply air stream<br />

from a directional grille.<br />

2. Refrigerated pipe within a room.<br />

3. Chilled-water pipes alongside structural floor beams.<br />

4. Exposed steel beam at high level in a room having chilled-water pipes attached.<br />

5. Natural convector chilled-water finned pipe.<br />

30. Which water temperature flows through a chilled beam?<br />

1. 6–12 ◦ C.<br />

2. 4–18 ◦ C.<br />

3. Below room air dew-point.<br />

4. Minimum of room air temperature minus 10 ◦ C.<br />

5. Above room air dew-point.