Ventilation and air conditioning 173<br />

68. Which is a correct description of the dual-duct air-conditioning system?<br />

1. Duplicated supply and return air ducts.<br />

2. A reduced cost design.<br />

3. Simultaneous heating and cooling to adjacent rooms.<br />

4. Not used in commercial office buildings.<br />

5. Appropriate for low-energy new buildings.<br />

69. Which is a correct description of the induction unit air-conditioning system?<br />

1. Each room terminal unit has a secondary air circulation fan.<br />

2. Recirculation air is induced away from the air discharged to atmosphere by suction from<br />

the supply air fan.<br />

3. Recirculated room air is neither heated nor cooled.<br />

4. Each terminal induction unit has a 2-, 3- or 4-pipe heating and chilled-water distribution.<br />

5. Recirculated room air does not need filtration.<br />

70. What does FCU air-conditioning system stand for?<br />

1. Full conditioning unit.<br />

2. Face console unit.<br />

3. Full compressor unit.<br />

4. Fan coil unit.<br />

5. Failed compressor unit.<br />

71. Which is a correct description of the fan coil unit air-conditioning system?<br />

1. Terminal unit used in an induction system.<br />

2. An FCU is a small AHU.<br />

3. Anything having a fan.<br />

4. Room air conditioner with a fan.<br />

5. Electric heating coil with a supply air fan.<br />

72. Which is appropriate for an FCU?<br />

1. Can be around the size of a suitcase.<br />

2. Does not always contain a fan.<br />

3. The unit that takes heated and cooled streams of air from different ducts, mixes them<br />

and supplies conditioned air into the zone.<br />

4. Potential direct replacement for an induction unit.<br />

5. Always large enough to walk around inside it.<br />

73. Which of these applies to packaged room air-conditioning units?<br />

1. Always connected to a ducted air system.<br />

2. Always connected to a central chilled-water plant system.<br />

3. Each unit has a refrigeration compressor.<br />

4. Always very quiet operation.<br />

5. Power demand not exceeding 250 W.<br />

74. Which is not correct for packaged room air-conditioning units?<br />

1. Small applications such as home single office and motel room.<br />

2. Stand-alone unit used for large computer server rooms.<br />

3. Silent and have no servicing requirement.