172 Ventilation and air conditioning<br />

62. Which of these is a sensible heating process line on a psychrometric chart?<br />

1. Straight line between two dry-bulb temperatures at constant specific enthalpy.<br />

2. Line between two dry-bulb temperatures at constant percentage saturation.<br />

3. Straight line between two dry-bulb temperatures at constant moisture content from<br />

right to left.<br />

4. Angled straight line between two dry-bulb temperatures from left to right.<br />

5. Straight line between two dry-bulb air temperatures at constant moisture content from<br />

left to right.<br />

63. Which of these does not correctly describe a cooling process line on a psychrometric chart?<br />

1. Cannot be precisely drawn on the chart due to variation of air percentage saturation<br />

within the air spaces around a cooling and dehumidification coil.<br />

2. Only the end points of the line are known precisely.<br />

3. Line drawn represents overall picture of cooling process through the coil.<br />

4. Curved line downwards from right to left between two moisture contents.<br />

5. Straight line angled downwards between two pairs of coordinates from air dry-bulb<br />

temperature and moisture content.<br />

64. Which of these describes the leaving air condition when warm humid air enters a chilledwater<br />

cooling coil?<br />

1. Higher moisture content.<br />

2. Higher specific enthalpy.<br />

3. Same moisture content.<br />

4. Lower dry-bulb air temperature and around 90% saturation.<br />

5. 100% saturated air at same moisture content.<br />

65. Which correctly describes cooling processes on a psychrometric chart?<br />

1. Reduces percentage saturation.<br />

2. Reduces air wet-bulb temperature.<br />

3. Maintains air at constant specific enthalpy.<br />

4. Maintains constant air wet-bulb temperature.<br />

5. Does not change air specific volume.<br />

66. Which does not correctly describe humidification processes on a psychrometric chart?<br />

1. Water sprays onto a chilled-water cooling coil.<br />

2. Steam injection provides better air cleanliness.<br />

3. Straight line moving away from 100% saturation curve.<br />

4. Straight line moving towards the 100% saturation curve.<br />

5. Adiabatic saturation line.<br />

67. Which is correct about a VAV air-conditioning system?<br />

1. Setting a minimum supply air flow rate at each terminal unit avoids dumping cool air<br />

onto occupants.<br />

2. Always requires terminal reheat coil.<br />

3. Stands for vortices-activated valve.<br />

4. Stands for volume-activated variable flow system.<br />

5. One terminal unit serves two zone orientations.