Error Codes 112/149<br />

Status & Error Codes TCP_<strong>IP</strong>-Task<br />

Error Code (Definition) Value Description<br />

TLR_E_TCP_ERR_MAX_<br />

DATA_LEN_EXCEEDED_ UDP_CMD_ SEND<br />

TLR_E_TCP_ERR_SOCKET_<br />

STATE_TCP_CMD_WAIT _CONNECT<br />

TLR_E_TCP_ERR_SOCKET_<br />

STATE_TCP_CMD_CONNECT<br />

TLR_E_TCP_ERR_SOCKET_<br />

STATE_TCP_CMD_SEND<br />

TLR_E_TCP_ERR_NO_FREE_<br />

QUEUE_ELEMENT_TCP_ CMD_ SEND<br />

TLR_E_TCP_ERR_NO_FREE_<br />

QUEUE_ELEMENT_UDP_ CMD_SEND<br />

TLR_E_TCP_ERR_NO_ETH_<br />

OUT_BUFFER_UDP_CMD_ SEND<br />

0xC0080141 The maximum UDP data count n in<br />

command TCP<strong>IP</strong>_UDP_CMD_SEND_<br />

REQ has exceeded. See parameter ulLen.<br />

The maximum value <strong>for</strong> n is<br />

TCP<strong>IP</strong>_MAX_UDP_DATA_CNT (1472).<br />

0xC0080200 The command<br />

TCP<strong>IP</strong>_TCP_CMD_WAIT_CONNECT_<br />

REQ cannot be executed, because the<br />

socket is in an inappropriate state.<br />

0xC0080201 The command<br />

TCP<strong>IP</strong>_TCP_CMD_CONNECT_REQ<br />

cannot be executed, because the socket is<br />

in an inappropriate state.<br />

0xC0080202 The command<br />

TCP<strong>IP</strong>_TCP_CMD_SEND_REQ cannot be<br />

executed, because the socket is in an<br />

inappropriate state.<br />

0xC0080210 The TCP send command<br />

TCP<strong>IP</strong>_TCP_CMD_SEND_REQ must be<br />

rejected, because the list of free queue<br />

elements is empty. Remark: Per default<br />

configuration, the initial size of this list is<br />

128. Every send command<br />

(TCP<strong>IP</strong>_TCP_CMD_SEND_REQ or<br />

TCP<strong>IP</strong>_UDP_CMD_SEND_REQ) occupy<br />

one queue element, until the confirmation<br />

command is given back to the application.<br />

To avoid this resource problem, the<br />

application must reduce the count of open<br />

send jobs over all sockets.<br />

0xC0080211 The UDP send command<br />

TCP<strong>IP</strong>_UDP_CMD_SEND_REQ must be<br />

rejected, because the list of free queue<br />

elements is empty. Remark: Per default<br />

configuration, the initial size of this list is<br />

128. Every send command<br />

(TCP<strong>IP</strong>_TCP_CMD_SEND_REQ or<br />

TCP<strong>IP</strong>_UDP_CMD_SEND_REQ) occupy<br />

one queue element, until the confirmation<br />

command is given back to the application.<br />

To avoid this resource problem, the<br />

application must reduce the count of open<br />

send jobs over all sockets.<br />

0xC0080212 The UDP send command<br />

TCP<strong>IP</strong>_UDP_CMD_SEND_REQ must be<br />

rejected, because all outgoing Ethernet<br />

buffers are occupied.<br />

TLR_E_TCP_ERR_MCAST_ CREATE 0xC0080220 Failed to create an <strong>IP</strong> Multicast group.<br />

TLR_E_<strong>IP</strong>_ERR_DEST_<br />

UNREACHABLE_<strong>IP</strong>_CMD_ PING<br />

TLR_E_TCP_ERR_DEST_<br />

UNREACHABLE_TCP_UDP_ CMD_CLOSE<br />

0xC0070300 The target <strong>IP</strong> address ulIpAddr in<br />

command TCP<strong>IP</strong>_<strong>IP</strong>_CMD_PING_REQ is<br />

not reachable.<br />

0xC0080301 Command<br />

TCP<strong>IP</strong>_TCP_UDP_CMD_CLOSE_REQ:<br />

The destination (host, network, or port) is<br />

unreachable.<br />

<strong>DTM</strong> <strong>for</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong> | Configuration of <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong><br />