Settings 32/149<br />

3.2.4.4 Driver Parameters <strong>for</strong> netX Driver - TCP/<strong>IP</strong> Connection<br />

The settings of the driver parameters <strong>for</strong> the TCP/<strong>IP</strong> connection are made<br />

via the netX Driver / TCP Connection configuration dialog.<br />

Open the TCP Connection dialog via navigation area Settings ><br />

Driver > netX Driver.<br />

The dialog netX Driver is displayed:<br />

Select TCP Connection.<br />

Figure 11: netX Driver > TCP Connection<br />

Parameter Meaning Range of Value / Value<br />

Enable TCP Connector<br />

(Restart of ODM<br />

required)<br />

checked: The netX Driver can communicate via the TCP/<strong>IP</strong><br />

interface.<br />

unchecked: The netX Driver can not communicate via the<br />

TCP/<strong>IP</strong> interface.<br />

If the check mark <strong>for</strong> Enable TCP Connector is set or<br />

removed, then the ODM server must be restarted 1 , to make<br />

the new setting valid.<br />

_______<br />

1<br />

Restart the ODM server via the ODMV3 Tray Application:<br />

-In the foot line click to using the right mouse key.<br />

- In the context menu select Service > Start.<br />

Select <strong>IP</strong> Range Via Select <strong>IP</strong> Range already created <strong>IP</strong> ranges can be<br />

selected.<br />

Via an additional <strong>IP</strong> range can be added.<br />

Via an <strong>IP</strong> range can be deleted.<br />

Scan Timeout [ms] With the scan timeout can be set, how long to wait <strong>for</strong> a<br />

response during a connection is established.<br />

checked,<br />

unchecked;<br />

Default:<br />

unchecked<br />

10 … 10000 [ms];<br />

Default: 100 ms<br />

<strong>DTM</strong> <strong>for</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong> | Configuration of <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong><br />

DOC061201OI06EN | Revision 6 | English | 2010-08 | Released | Public © <strong>Hilscher</strong>, 2006-2010

Hooray! Your file is uploaded and ready to be published.