Getting Started 19/149<br />
# Step Short Description For detailed in<strong>for</strong>mation<br />
see section<br />
10 Assign <strong>Scanner</strong><br />
device once more<br />
(with firmware)<br />
11 Configure Adapter<br />
device<br />
12 Configure <strong>Scanner</strong><br />
device<br />
In the <strong>Scanner</strong> <strong>DTM</strong> configuration dialog:<br />
- select Settings > Device Assignment,<br />
- select Scan,<br />
- select the <strong>Scanner</strong> device (with loaded<br />
firmware),<br />
- there<strong>for</strong>e check the appropriate checkbox,<br />
- select Apply,<br />
- close the <strong>Scanner</strong> <strong>DTM</strong> configuration dialog via<br />
OK.<br />
Configure the Adapter device.<br />
- Double click to the device icon of the Adapter.<br />
- The Adapter <strong>DTM</strong> configuration dialog is<br />
displayed.<br />
In the Adapter <strong>DTM</strong> configuration dialog:<br />
- select Configuration > Modules (<strong>for</strong> modular<br />
<strong>DTM</strong> only),<br />
- configure the modules of the modular<br />
<strong>EtherNet</strong>/<strong>IP</strong> Adapter,<br />
- select Configuration > Electronic Keying,<br />
- select the keying method and configure it if<br />
necessary,<br />
- select Configuration > Connection,<br />
- configure the connection points,<br />
- select Configuration > Assembly,<br />
- configuren Instance ID and Data length,<br />
- configure a modular device according to the<br />
description Configuring a modular <strong>EtherNet</strong>/<strong>IP</strong><br />
Adapter,<br />
- close the Adapter <strong>DTM</strong> configuration dialog via<br />
OK.<br />
Configure the <strong>Scanner</strong> device.<br />
- Double click to the device icon of the <strong>Scanner</strong>.<br />
- The <strong>Scanner</strong> <strong>DTM</strong> configuration dialog is<br />
displayed.<br />
In the Scannner <strong>DTM</strong> configuration dialog:<br />
- select Configuration > Network Settings,<br />
- set the Network Settings,<br />
- select Configuration > Scanlist,<br />
- select the required device/s and set the<br />
<strong>IP</strong> address of the adapter,<br />
- select Configuration > Process data,<br />
- set symbolic names <strong>for</strong> the configured modules<br />
or signals.<br />
- select Configuration > Address table,<br />
- set the device address, if necessay,<br />
- select Configuration > <strong>Scanner</strong> Settings,<br />
- set the <strong>Scanner</strong> Settings.<br />
- close the <strong>Scanner</strong> <strong>DTM</strong> configuration dialog via<br />
OK.<br />
13 Save project Depending of the frame application.<br />
For the configuration software:<br />
- select File > Save.<br />
14 Connect <strong>Scanner</strong><br />
device<br />
15 Download<br />
Configuration<br />
Depending of the FDT Container.<br />
For netDevice:<br />
- right click to the device icon of the <strong>Scanner</strong>,<br />
- select context menu entry Connect.<br />
Depending of the FDT Container.<br />
For netDevice:<br />
- right click to the device icon of the <strong>Scanner</strong>,<br />
- select context menu entry Download.<br />
Selecting the Device once<br />
more (with Firmware)<br />
(See “User Manual Generic<br />
<strong>EtherNet</strong>/<strong>IP</strong> Adapter <strong>DTM</strong><br />
<strong>for</strong> <strong>EtherNet</strong>/<strong>IP</strong> Adapter<br />
<strong>Devices</strong> and Modular<br />
Generic <strong>EtherNet</strong>/<strong>IP</strong> Adapter<br />
<strong>DTM</strong> <strong>for</strong> modular<br />
<strong>EtherNet</strong>/<strong>IP</strong> Adapter<br />
<strong>Devices</strong>)<br />
Configuring Device<br />
Parameters<br />
Network Settings<br />
Scanlist<br />
Process Data<br />
Address Table<br />
<strong>Scanner</strong> Settings<br />
(See User Manual of the<br />
Frame Application)<br />
Connecting/Disconnecting<br />
Device<br />
<strong>DTM</strong> <strong>for</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong> | Configuration of <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong><br />
DOC061201OI06EN | Revision 6 | English | 2010-08 | Released | Public © <strong>Hilscher</strong>, 2006-2010<br />
Page<br />
40<br />
-<br />
22<br />
48<br />
49<br />
51<br />
52<br />
55<br />
-<br />
90<br />
Download Configuration 91