Error Codes 138/149<br />
9.8 Error Codes netX Driver<br />
9.8.1 CIFX API Transport Error Codes<br />
Error Code (Definition) Value Description<br />
CIFX_TRANSPORT_SEND_TIMEOUT 0x800D0001L Time out while sending data<br />
CIFX_TRANSPORT_RECV_TIMEOUT 0x800D0002L Time out waiting <strong>for</strong> incoming data<br />
CIFX_TRANSPORT_CONNECT 0x800D0003L Unable to communicate to the deviceno<br />
answer<br />
CIFX_TRANSPORT_ABORTED 0x800D0004L Transfer has been aborted due to keep<br />
alive timeout or interface detachment<br />
CIFX_CONNECTOR_FUNCTIONS_READ_ERR<br />
OR<br />
0x800D0010L Error reading the connector functions<br />
from the DLL<br />
CIFX_CONNECTOR_IDENTIFIER_TOO_LONG 0x800D0011L Connector delivers an identifier longer<br />
than 6 characters<br />
CIFX_CONNECTOR_IDENTIFIER_EMPTY 0x800D0012L Connector delivers an empty dentifier<br />
CIFX_CONNECTOR_DUPLICATE_IDENTIFIER 0x800D0013L Connector identifier already used<br />
Table 69: CIFX API Transport Error Codes<br />
9.8.2 CIFX API Transport Header State Error Codes<br />
Error Code (Definition) Value Description<br />
CIFX_TRANSPORT_ERROR_UNKNOWN 0x800E0001L Unknown error code in transport header<br />
CIFX_TRANSPORT_CHECKSUM_ERROR 0x800E0002L CRC16 checksum failed<br />
CIFX_TRANSPORT_LENGTH_INCOMPLETE 0x800E0003L Transaction with inclomplete length<br />
detected<br />
CIFX_TRANSPORT_DATA_TYPE_UNKOWN 0x800E0004L Device does not support requested data<br />
type<br />
CIFX_TRANSPORT_DEVICE_UNKNOWN 0x800E0005L Device not availableunknown<br />
CIFX_TRANSPORT_CHANNEL_UNKNOWN 0x800E0006L Channel not availableunknown<br />
CIFX_TRANSPORT_SEQUENCE 0x800E0007L Sequence error detected<br />
CIFX_TRANSPORT_BUFFEROVERFLOW 0x800E0008L Buffer overflow detected<br />
CIFX_TRANSPORT_RESOURCE 0x800E0009L Device signals out of resources<br />
CIFX_TRANSPORT_KEEPALIVE 0x800E000AL Device connection monitoring error<br />
(Keep alive)<br />
CIFX_TRANSPORT_DATA_TOO_SHORT( 0x800E000BL Received transaction data too short<br />
Table 70: CIFX API Transport Header State Error Codes<br />