DTM for EtherNet/IP Scanner Devices - Hilscher
DTM for EtherNet/IP Scanner Devices - Hilscher
DTM for EtherNet/IP Scanner Devices - Hilscher
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Configuration 56/149<br />
4.6.1 Start of Bus Communication<br />
4.6.2 Application Monitoring<br />
Figure 31: <strong>Scanner</strong> Settings > Start of Bus Communication<br />
If Automatically by device is selected, the <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> device<br />
starts with the data exchange on the bus after the initializing has been<br />
ended.<br />
When Controlled by application is selected, the application program must<br />
activate the data exchange on the bus.<br />
Note: The setting options under Start of Bus Communication <strong>for</strong> client<br />
specific variants of the configuration software can differ from the setting<br />
options displayed here.<br />
Figure 32: <strong>Scanner</strong> Settings > Application Monitoring<br />
The Watchdog time determines the time within which the device watchdog<br />
must be re-triggered from the application program while the application<br />
program monitoring is activated. When the watchdog time value is equal to<br />
0 the watchdog is deactivated and the application program monitoring is<br />
deactivated too.<br />
The permissible range of values of the watchdog time is 20 to 65535. By<br />
default the watchdog time value equals to 1000 ms.<br />
Watchdog time Range of Value / Value<br />
Permissible range of values 20 … 65535 ms<br />
Default 1000 ms<br />
The software watchdog is deactivated. 0 ms<br />
Table 22: Range of Value / Value <strong>for</strong> the Watchdog time<br />
Note: The setting options under Application Monitoring <strong>for</strong> client<br />
specific variants of the configuration software can differ from the setting<br />
options displayed here.<br />
<strong>DTM</strong> <strong>for</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong> | Configuration of <strong>EtherNet</strong>/<strong>IP</strong> <strong>Scanner</strong> <strong>Devices</strong><br />
DOC061201OI06EN | Revision 6 | English | 2010-08 | Released | Public © <strong>Hilscher</strong>, 2006-2010