Extended Diagnosis 66/149<br />
6.2 Task In<strong>for</strong>mation<br />
Figure 39: Extended Diagnosis > [Folder Name] > Task In<strong>for</strong>mation<br />
Name Description<br />
Identifier Identification number of the task<br />
Major version Task version, contains incompatible changes<br />
Minor version Task version, contains compatible changes<br />
Maximum package size Maximum package size, which the task sends<br />
Default Queue Queue handle, which is accessible via DPM by<br />
mailbox.<br />
UUID Unique user ID, 16 Byte indicator used <strong>for</strong> task<br />
identification and its affiliation e. g. to a stack (therein<br />
different identification data are coded in).<br />
Init result Error Code, 0= no Error<br />
The description of the error codes can be found in this<br />
manual or in the corresponding software reference<br />
manuals.<br />
Table 30: Extended Diagnosis > [Folder Name] > Task In<strong>for</strong>mation<br />