<strong>VessRAID</strong> 1000i Series Product Manual<br />

Disk Array Operational Status<br />

• OK – The normal state of a disk array. For RAID Levels other than RAID 0<br />

(Striping), the disk array has full redundancy.<br />

• Synchronizing – When you first create a disk array, the disk array<br />

synchronizes. During that time, your data is available. However, access will<br />

be slower until synchronizing is done.<br />

• Critical/Degraded – This condition results from a physical drive failure. Your<br />

data is still available. However, the disk array has lost redundancy (fault<br />

tolerance). You must determine the cause of the problem and correct it. See<br />

“Critical & Offline Disk Arrays” on page 302.<br />

• Rebuilding – This condition is temporary. When a physical drive has been<br />

replaced, the disk array automatically begins rebuilding in order to restore<br />

redundancy (fault tolerance). Your data is still available. However, access will<br />

be slower until rebuilding is done.<br />

• Transport Ready – The result of a successful Prepare for Transport<br />

operation. You remove the physical drives of this disk array and move them<br />

to another enclosure or to different drive slots in the same enclosure. After<br />

you relocate the physical drives, the disk array status will show OK.<br />

Adjustable Items<br />

• Alias – Optional.<br />

• Media Patrol – Enabled or disabled.<br />

• PDM – Enabled or disabled.<br />

See “Making Disk Array Settings” below.<br />

Making Disk Array Settings<br />

To make Disk Array settings:<br />

1. Click the Subsystem icon in Tree View.<br />

2. Click the Disk Arrays icon.<br />

3. Click the Disk Array icon.<br />

4. Click the Settings tab in Management View.<br />

5. Optional. Enter an alias in the Disk Array Alias field.<br />

Maximum of 31 characters. Use letters, numbers, space between words,<br />

and underscore. An alias is optional.<br />

6. To enable Media Patrol support, check the Media Patrol box.<br />

7. To enable PDM support, check the PDM box.<br />

8. Click the Submit button.<br />

120

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!