<strong>VessRAID</strong> 1000i Series Product Manual<br />

Setting Temperature Thresholds<br />

To change temperature thresholds:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Enclosure Settings and press Enter.<br />

4. Highlight the Temperature Warning threshold you want to change.<br />

5. Press the backspace key to erase the current value.<br />

6. Type a new interval value in degrees C.<br />

7. Press Ctrl-A to save your settings.<br />

Checking the Batteries<br />

This feature enables you monitor and recondition the subsystem battery or<br />

batteries.<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Batteries and press Enter.<br />

4. Highlight the battery you want to monitor and press Enter.<br />

Battery Notes<br />

Each battery works with a controller. If the battery is present in the subsystem but<br />

the corresponding controller is not present, the battery will not appear in the<br />

interface.<br />

If a battery does not reflect normal conditions and it is not currently under<br />

reconditioning, run the Recondition function before you replace the battery. See<br />

“Reconditioning a Battery” on page 153.<br />

Reconditioning fully discharges, then fully recharges the battery. During<br />

reconditioning, if the Adaptive Writeback Cache function is enabled, the controller<br />

cache is set to Write Thru. After reconditioning, the cache is reset to Write Back.<br />

See “Making Controller Settings” on page 147.<br />

If a battery reaches the threshold temperature while charging or discharging, the<br />

charge or discharge pauses and the blower runs at high speed until the battery<br />

temperature falls below the threshold.<br />

If the battery does not maintain normal values after a Recondition, replace the<br />

battery. See “Replacing the Cache Battery” on page 240.<br />

<strong>VessRAID</strong> automatically reconditions the battery every two months.<br />

When you install a new battery, the cycle count shows 0. <strong>VessRAID</strong> automatically<br />

runs a recondition on the battery to verify it. If you restart the subsystem or<br />

152