<strong>VessRAID</strong> 1000i Series Product Manual<br />

Ranges of Disk Array Expansion<br />

The Windows 2000 and Windows XP (32-bit) operating systems support a<br />

10-byte LBA format. As a result, these OSes can only recognize 4 billion<br />

addresses. If you create a logical drive using the default 512 B sector size, the<br />

logical drive will be limited to 2 TB of data, even if there is more space available<br />

on your disk drives.<br />

This limitation does not apply to Windows XP (64-bit), 2003 Server, Vista, and<br />

Linux OSes with the 2.6 kernel. Linux OSes with the 2.4 kernel do not support<br />

variable sector sizes, therefore you cannot apply the solution described here to<br />

those OSes.<br />

Note that once you create your logical drive, you cannot change the size of the<br />

sectors. Nor can you increase the number of address blocks that the OS<br />

recognizes.<br />

You can direct WebPAM PROe to expand a logical drive beyond the maximum<br />

expansion size. When the expansion is finished:<br />

• WebPAM PROe will show the logical drive in the desired size.<br />

• Your operating system might show the logical drive at the maximum size<br />

listed in the table below.<br />

• Additional capacity might appear as unpartitioned and unformatted.<br />

270<br />

Important<br />

• The Target disk array may require more physical drives than<br />

the Source disk array<br />

• If the Target disk array requires an EVEN number of physical<br />

drives but the Source disk array has an ODD number, ADD a<br />

physical drive as part of the migration process<br />

• You cannot reduce the number of physical drives in your disk<br />

array, even if the Target disk array requires fewer physical<br />

drives than the Source disk array<br />

• RAID 1 (mirroring) works with two drives only. Only a singledrive<br />

RAID 0 disk array can migrate to RAID 1. Other RAID<br />

Levels use too many drives to migrate<br />

• You cannot migrate a disk array when it is Critical or<br />

performing activities such as Synchronizing, Rebuilding, and<br />

PDM<br />

• For RAID 6 or RAID 60, you can only migrate between these<br />

two RAID levels. Destination RAID 60 axles can have up to<br />

32 physical drives. Other limitations might apply