Reported Event Corrective Action<br />

291<br />

Chapter 9: Troubleshooting<br />

Blowers are functioning Normal.<br />

normally<br />

Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it.<br />

See page 238.<br />

Blower status is unknown Check for airflow out of the cooling unit. If there is<br />

none, check for proper installation.<br />

Cache<br />

BBU flushing has started <strong>VessRAID</strong>’s cache is being flushed.<br />

BBU flushing has ended <strong>VessRAID</strong>’s cache has been flushed.<br />

BBU flushing has failed <strong>VessRAID</strong>’s cache could not be flushed. Check your<br />

cache flush interval setting. See page 96 (WebPAM<br />

PROe) or page 147 (CLU).<br />

Controller<br />

The controller<br />

parameter(s) changed by<br />

user<br />

The controller has new<br />

crash information<br />

Controller temperature is<br />

above the threshold/<br />

warning threshold<br />

Controller temperature is<br />

above the critical<br />

threshold<br />

Disk Array<br />

New disk array has been<br />

created<br />

Disk array has been<br />

deleted<br />

Disk array has been<br />

added<br />

Disk array has been<br />

removed<br />

Disk array settings have<br />

been changed<br />

The user successfully changed controller settings.<br />

See page 96 (WebPAM PROe) or page 147 (CLU).<br />

Check the event logs. See page 53 and 54 (WebPAM<br />

PROe) or page 186 (CLU)<br />

The <strong>VessRAID</strong> controller is overheating. Check for<br />

airflow around and through the controller, and verify<br />

that all fans are working. Replace fans as needed.<br />

The <strong>VessRAID</strong> controller is seriously overheating.<br />

Check for airflow around and through the controller,<br />

and verify that all fans are working. Replace fans as<br />

needed.<br />

Result of settings or user action. Normal.<br />

Result of settings or user action. Normal.<br />

Result of settings or user action. Normal.<br />

The physical drives of the disk array were removed<br />

from the enclosure.<br />

The user successfully disk array settings. See<br />

page 120 (WebPAM PROe) or page 163 (CLU).