23.03.2013 Views

VessRAID Setup - Promise Technology, Inc.

VessRAID Setup - Promise Technology, Inc.

VessRAID Setup - Promise Technology, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

205<br />

Chapter 5: Management with the CLU<br />

Shutting down the <strong>VessRAID</strong> – Serial Connection<br />

This function enables you to shutdown the <strong>VessRAID</strong> subsystem on a serial<br />

connection. Additional action is required, as described below.<br />

To shutdown the <strong>VessRAID</strong>:<br />

1. From the Main Menu, highlight Additional Info and Management and press<br />

Enter.<br />

2. Highlight Shutdown or Restart and press Enter.<br />

3. Do one of the following actions:<br />

• Highlight Option and press the spacebar to display Shutdown.<br />

• Highlight Option and press the spacebar to display Poweroff.<br />

4. Highlight Submit and press Enter.<br />

A warning message appears.<br />

5. Press Y to continue.<br />

6. When you see the following message:<br />

Shutdown complete. It is now safe to power off the subsystem.<br />

Do one of the following actions:<br />

• If you chose the Shutdown Option, manually turn off the power supply<br />

switch (both switches with redundant power supplies) on the back of the<br />

subsystem.<br />

• If you chose the Poweroff Option, the subsystem powers down<br />

automatically. On subsystems with redundant power supplies, unplug<br />

the power cords and plug them back in, to activate the power switches.<br />

Caution<br />

After you power off the subsystem, wait at least 10 seconds before<br />

you power on the subsystem again.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!