Restarting Subsystem over a Telnet Connection<br />

235<br />

Warning<br />

Chapter 7: Maintenance<br />

Do not restart the <strong>VessRAID</strong> during a firmware upgrade<br />

procedure. Wait until the upgrade is done and you are prompted to<br />

restart.<br />

To restart the <strong>VessRAID</strong> subsystem on a Telnet connection:<br />

1. From the Main Menu, highlight Additional Info and Management, and press<br />

Enter.<br />

2. Highlight Shutdown or Restart and press Enter.<br />

3. Press the spacebar to display Restart then press Enter.<br />

A warning message appears.<br />

4. Press Y to continue.<br />

The screen will go blank.<br />

5. Wait for two to three minutes.<br />

6. Re-establish your Telnet connection to the <strong>VessRAID</strong> CLU.<br />

If you cannot re-establish a connection, wait 30 seconds, then try again.<br />

Restarting Subsystem over a Serial Connection<br />

Warning<br />

Do not restart the <strong>VessRAID</strong> during a firmware upgrade<br />

procedure. Wait until the upgrade is one and you are prompted to<br />

restart.<br />

To restart the <strong>VessRAID</strong> subsystem on a serial connection:<br />

1. From the Main Menu, highlight Additional Info and Management, and press<br />

Enter.<br />

2. Highlight Shutdown or Restart and press Enter.<br />

3. Press the spacebar to display Restart then press Enter.<br />

A warning message appears.<br />

4. Press Y to continue.<br />

The screen will display shutdown and startup functions.<br />

5. When the Login: prompt appears, log into the CLU again.